Parker Solenoid Valve E321G3910
There is no price at present, you can Request a Quote
People who bought this item also viewed
Parker Solenoid Valve 121Z2323
Parker Solenoid Valve E321G37
KOGANEI Solenoid Valve F10T2-A1-DC24V
ARK Solenoid Valve KVF3130-DC24V
Bristol Compressor H20B193ABH
Siemens Sensor 3RG4148-3CD00
YUKEN Overflow Valve RBG-06-10
YEOSHE Piston Pump V70A2L10X
KCL Vane Pump KT6D-031-1R00-B4
Bosch Filter AQ7100P
EMERSON Sight Glass AMI-1MM4
Hitachi Expansion Valve Coil EPF32
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KOGANEI Air Cylinder CDA16X20
Omron Switch Z-15EW
Iwaki Magnet Pump EHN-B31VHMR
SHAKO Air Cylinder PCL32C500
Recent related posts
-
08/24/2020
How to switch freely between cooling, heating and dehumidification modes
Nowadays, the air conditioner has become a must-have household appliance for every household. In different seasons, for us, we can adjust the temperature with our fingers and realize the switching of different functions.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/26/2020
Features of scroll refrigeration compressor:
Advantages of scroll refrigeration compressors:<br></br> 1. There is no reciprocating mechanism, so the structure is simple, small in size, light in weight, few parts (especially few wearing parts), and high reliability;<br></br>
-
12/02/2021
Calibration of Rosemount Transmitter
When adjusting the transmitter, please turn off the protection setting, which is usually the red switch in front of the meter and its status may be ON or OFF.
-
09/06/2020
How to distinguish whether air compressor oil has impurities
Everyone knows that screw air compressors have high requirements for oil. However, air compressors are easily mixed with others during use, which will not only affect the work of the air compressor, but also easily cause damage to the air compressor.
-
07/03/2020
Centrifugal Air Compressor Market Growth Factors and Business Development Strategy from 2020-2026 | Atlas Copco, Hitachi Industrial Equipment Systems, General Electric
Global Booster Compressor Market: Industry Analysis and Forecast (2018-2026) – By Cooling Type, Compression Stage, Pressure,End User and Geography Global Booster Compressor Market was value US$ 1.80Bn in 2017 and is expected to reach US$ 3.20Bn by 2026, at a CAGR of 7.46 % during a forecast period.
-
06/14/2020
Business management logic of cold storage management system
Business management logic of cold storage management system Nowadays, the development of the cold storage industry is fast, but the scale of the cold storage enterprises is uneven.
-
06/14/2020
The reasons for the high temperature of the compressor discharge are
The reasons for the high temperature of the compressor discharge are (1) The clearance in the compressor cylinder is too large; (2) The suction and exhaust valves and piston ring of the compressor are damaged; (3) The compressor safety bypass valve 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
07/27/2020
The working principle of screw unit and common failure analysis
1. Refrigeration cycle and pressure enthalpy diagram<br></br> The refrigeration cycle of a screw chiller can be represented by a pressure-enthalpy diagram. The main state points are shown in the diagram, which will be used in the following discussion.
-
07/16/2020
Compressor overheating
The compressor is overheated, causing it to stop shortly after start-up (protector action). Please check whether it is:; Insufficient or excessive refrigerant, please fill the leak and evacuate, add enough refrigerant or release excess refrigerant. The capillary assembly (including the filter) is clogged and the suction temperature rises. Please replace the capillary assembly.