6 possible reasons why the air conditioner is not cooling
The reasons why the air conditioner is not refrigerated are divided into non-air-conditioning faults and air-conditioning faults. Today we share the reasons for non-air-conditioning faults.
One of the reasons why the air conditioner is not cooling
Insufficient Freon (commonly known as "not enough refrigerant")
1. Low pressure 0.45MP 2. High pressure above 2.5MP 3. Static pressure 1.1-1.2MP. This is a normal situation and usually occurs in old air conditioners that have been used for three to four years. The air conditioner is not completely uncooled, but the cooling effect is reduced. This is because old-fashioned air conditioners use Freon as a refrigerant, which will evaporate after long-term use. Therefore, users only need to add a little to the regular air conditioning repair point. In addition, it does not rule out the problems of Freon leakage and the machine itself caused by improper installation.
The second reason why the air conditioner is not cooling
Insufficient supply voltage
The normal starting voltage of the air conditioner is 220V+-10%. In our country's power supply system with phase voltage of 220V and line voltage of 380V, almost all compressors above 200V can be started. When it is above 180V, 70-80% can be started, when it is above 160V, only a few can start. I have done the experiment myself. It is almost impossible to start below 160V. According to experience, the compressor starting voltage is more reliable when it is above 190V.
The third reason why the air conditioner is not cooling
Air conditioning power is not enough
The general selection principle is: 150-250W/m2 for cooling and 250-350W/m2 for heating. In addition, factors such as space height, layer orientation, sealing performance and residential population must be considered.
Four reasons why the air conditioner is not cooling
The ambient temperature is too high
There is a more common saying: when the outdoor unit is in an environment above 43°, most air conditioners are difficult to transfer indoor heat to the outdoors, resulting in no cooling.
Five reasons why the air conditioner is not cooling
The air conditioner is not cleaned and maintained for a long time
If you want the air conditioner to function normally without affecting human health, and to extend the life as much as possible, obviously, it is impossible to ignore it once you buy it and install it. Because the outdoor unit is exposed to the outdoors, it is easy to absorb dust and debris. If it is not cleaned for a long time, it will affect the heat dissipation performance of the machine and reduce the cooling effect of the air conditioning. The indoor unit is related to human health. If it is not cleaned for a long time, it will breed bacteria, pollute the air, and make people sick.
Six reasons why the air conditioner is not cooling
The copper pipe connecting the indoor unit and the outdoor unit is too long
The maximum allowable length of the connecting pipe of the air conditioner cannot exceed 8 meters for one horse, 10 meters for 1.5-2 horses, and 15 meters for more than 2 horses. The height difference between indoor and outdoor units should not exceed 5 meters.
6 possible reasons why the air conditioner is not cooling
Recent related posts
-
07/29/2020
6 possible reasons why the air conditioner is not cooling
6 possible reasons why the air conditioner is not cooling<br></br> The reasons why the air conditioner is not refrigerated are divided into non-air-conditioning faults and air-conditioning faults. Today we share the reasons for non-air-conditioning faults.
-
07/29/2020
R410a refrigerant vacuum training
The first step of vacuuming<br></br> Steps for installing and connecting the internal and external machines...Connect the pipes connecting the internal and external machines, tighten...
-
07/29/2020
Adding fluoride to the air conditioner is tricky, don't be fooled!
remind<br></br> In the hot weather, many citizens have begun to use air conditioners to remind everyone to be careful not to be fooled by unnecessary "air conditioner filling
-
07/29/2020
Common sense of wire and cable calculation
What is the maximum current and power that a square wire can pass? How much wire is used for 100KW of electricity for project construction? Large wires cause waste, and small wires have more serious consequences. Here I share with you my estimation experience.
-
07/29/2020
Pressure controller use and adjustment
Many pressure controllers are used in the refrigeration system, and the pressure is controlled by the on and off of the contacts. Mainly include high pressure pressure controller, low pressure pressure controller, high and low pressure pressure controller, pressure difference controller and oil pressure protection pressure controller.
-
07/29/2020
What to do if the air-conditioning copper pipe leaks
What should I do if the air-conditioning copper pipe leaks? Why is the air-conditioning copper pipe leaking? Everyone is familiar with copper pipes for air conditioning.
-
07/29/2020
Nine refrigerant leakage locations and solutions
There are many welds on the left and right sides of the evaporator, and there may be more leaks. The leak of the newly installed air conditioner is mainly due to the poor welding skills of the employees of the air conditioner manufacturer.
-
07/28/2020
Analysis of common failure causes of hermetic refrigeration compressors
. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.
-
07/28/2020
Method and steps to replace the refrigeration compressor
Cut off the power supply: Before replacing the compressor, be sure to cut off the power supply of the unit, otherwise there will be a risk of electric shock.
-
07/28/2020
How much does it cost to install a 120㎡ central air conditioner? What is the standard installation process?
Nowadays, central air-conditioning has lifted the veil of mystery and has begun to enter thousands of homes, and it has gradually become a trend.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SMC Solenoid Valve VFS5110-1DZB
Schneider Contactor LC1D15000P7C
KSK Oil SealTC(FKM)58X75X8
AirTAC Air Cylinder SGC200X850S
NSK Linear Guideway VH30GM