Inlet M.NPT: 1/4
Body and Valve Material: brass
Pressure Setting Range PSIG: 17-600
Height: 2.8
Wrenching hex: 7/8
Orifice Size Sq. Inch: .062
Pipe-Away Adapter P/N: B-9412-2
REGO Safety Valve PRV9432TP275
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
BRIDGE Welding Wire THQ-50HR
KOGANEI Solenoid Valve KFPV050-2-20
Siemens Circuit Breaker 5SL6101-7CC
Recent related posts
-
06/14/2020
Detailed explanation of screw compressor structure and working principle
Detailed explanation of screw compressor structure and working principle Screw compressors, also known as screw compressors, include screw air compressors and screw process compressors (vinyl chloride compressors, etc.).
-
08/14/2023
Are Window Heat Pumps Efficient? (Window Heat Pump: Everything You Need to Know)
Window heat pumps (heat pump window units, window unit heat pumps) are a popular heating and cooling solution for homes and apartments. They are affordable, easy to install, and can help save energy compared to other heating and cooling options.
-
07/04/2020
Introducing the performance characteristics of Meiyou Le Maneurop compressor MTZ144
Introducing the performance characteristics of Meiyou Le Maneurop compressor MTZ144 Pictured here: the United States US Youle MANEUROP compressor MTZ144 Product features of MTZ144: 1. The design plan of the US Youle compressor is environmentally friendly, and the series compressors can run smoothly and reliably.
-
08/05/2020
Why does the refrigeration compressor produce overheat protection What matters should be paid attention to in the use of overload protector
The working principle and classification of the overload protector. The overload protector of the compressor for air conditioning generally adopts a snap-type bimetallic protector, which consists of a heating wire,
-
08/20/2020
Placement of the thermostatic valve bulb
The bulb should be as close as possible to the outlet of the evaporator and placed in close contact with the outlet pipe. In the part of the pipe section where the temperature bulb is in contact with the pipe,
-
06/14/2020
The main features of screw compressors What are the advantages of screw air compressors
Power balance is good. The screw compressor has no unbalanced inertial force, the machine can work smoothly at high speed, and it can be operated without foundation. It is particularly suitable for use as a mobile compressor, with small size, light weight ﰸ2 䀀 ᅵ皥
-
01/26/2023
How to Maintain a Pressure Transmitter
In order to prolong the service life of the pressure transmitter and reduce the error, regular inspection and maintenance are recommended, such as weekly inspection.
-
06/24/2020
Reasons and solutions of refrigerator not cooling
In the use of refrigerators, when there are more or less problems, I believe many people have encountered the reason why the refrigerator at home does not cool. What will you do when you encounter this situation? How much do you know about the reasons for the refrigerator not cooling? What? The following editor will introduce the reasons and solutions for the refrigerator not cooling, I hope to help you.
-
02/28/2024
A Comprehensive Guide to RV Refrigerator Fans: Basics, Types, Functions & Installation
Recreational vehicles (RVs) are synonymous with adventure and freedom, allowing enthusiasts to explore the open road without sacrificing the comforts of home. Among the crucial components of an RV is the refrigerator.
-
06/26/2020
What is the refrigerator compressor used for
Refrigerators use evaporative cooling or vaporization to absorb heat to achieve the purpose of refrigeration. The throat of the refrigerator is filled with a refrigerant known commercially as Freon, commonly known as refrigerant. A commonly used one is difluorodichloromethane, which is a colorless, odorless and non-toxic gas with a boiling point of 29°C. Freon is pressurized by the compressor when it is in a gas state.