Rockwell AB VFD Frequency Converter 20BD125A2AYNAEA0
People who bought this item also viewed
SIEMENS Servo Motor 1FK7080-5AF71-1EH0
Fanuc Servo Drive A06B-6140-H026
HENGSTLER Encoder RI32-O/20AR.14DB
Rockwell AB Power Supply 1606-XLE240EP
Siemens PLC 6ES7322-1FH00-0AA0
MITSUBISHI Spindle Amplifier MDS-DM2-SPV3-20080
Schneider Controller Module TSXCXP233
Fuji Relay TK-E224-36A
HAWKER Battery 3PzB300
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KOGANEI Air Cylinder NHBMPG-16-L
MAC Solenoid Valve 225B-111CA
Recent related posts
-
09/18/2020
The current sales model of air compressors
1. Head office→regional agent→distributor→salesman→customer (representing company: Fusheng, Atlas, etc.) ⑴. It takes about four stages to reach the customer, and the profit is also reduced considerably (because the intervention of the middleman increases the cost)
-
07/14/2020
Dutch company develops high-tech air-conditioning equipment: it can be cooled without electric energy
Dutch company develops high-tech air-conditioning equipment: it can be cooled without electric energy US media said that according to the International Energy Agency, by 2050, nearly 6 billion air conditioners will consume 37% of the world's electricity.
-
09/08/2020
Advantages and disadvantages of closed motor and open motor of air compressor
Air compressor enclosed motor: Protection grade: IP44, IP54, IP55 Advantages: 1) Wide application range. The air compressor driven by a closed motor can be used in places with poor environment. For example, there is a lot of dust and the fibers are flying. Factories and mining industries with corrosive gas and other surrounding areas.
-
04/11/2022
What Does an Expansion Valve Do?
Expansion valve is an important part of refrigeration system, which is generally installed between liquid storage tank and evaporator.
-
07/15/2020
ZP72KCE-TFD576.0 HP 60Hz (R410A) air conditioner Emerson Copeland compressor
What the editor will introduce today is the Emerson Copeland compressor ZP72KCE-TFD/5/7, which is suitable for R410A refrigerant at 60Hz three-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 6.0 hp. Other technical parameters can be downloaded from our company's website for inquiries.
-
01/09/2024
Cooling Towers: Operation Methods, Maintenance & Usage Precautions
Cooling towers are critical equipment used in industrial and commercial areas to cool fluids. In order to ensure its effective operation, increase its lifespan and maintain safety, correct operation methods, maintenance and upkeep knowledge, and usage precautions are crucial. In this article, we will delve into these aspects.
-
08/04/2020
This button on the remote control of the air conditioner is not used. Here is the secret of power saving →
Summer is here, and many families have begun to use air conditioners, but while enjoying the coolness, the rising electricity bills are also painful. I will teach you some power saving methods right away
-
07/19/2023
How Does a Scroll Compressor Work? Components, Principles, and Applications
Compressors are essential components in air conditioning and refrigeration systems. They are responsible for compressing the refrigerant gas, which is then circulated through the system to absorb and release heat.
-
08/31/2022
What is a Magnetic Contactor?
In many cases, the magnetic contactor is simply referred to as a contactor. It is an electrical appliance that uses the current flowing through the coil to generate a magnetic field to close the contacts to control the load in industrial electricity.
-
06/24/2020
How to add air conditioning refrigerant
Turn off the power supply of the air conditioner first; if all the light leaks, then you must evacuate before adding it; find the thick tube under the outdoor unit and add fluorine from here; you need to install the pressure gauge when adding fluorine Generally, it can be stopped at about 5 pressures; the temperature needs to be turned to the lowest when turning on the machine, and observe for about half an hour.