Product name | DC Fan |
Frame material | Aluminum |
Series | San Ace 120 |
Frame size(mm) | Square - 120mm L x 120mm H |
Frame thickness | 38.00mm |
Rated voltage[V] | 24VDC |
Rated current[A] | - |
Rated input[W] | 48 W |
Rated speed[min-1] | - |
Max. airflow[m3/min] | 7.28 m3/min |
Max. airflow[CFM] | 260.0 CFM |
Max. static pressure[Pa] | 341.2 Pa |
Max. static pressure[inchH2O] | 1.370 |
SPL[dB(A)] | 64.0 dB(A) |
Expected life[h] | - |
Sensor type | - |
IP rating | - |
PWM control function | - |
Bearing Type | Ball |
Fan Type | Tubeaxial |
Features | Locked Rotor Sensor |
RPM | 6000 RPM |
Termination | 3 Wire Leads |
Operating Temperature | -4 ~ 158~F (-20 ~ 70~C) |
Approval Agency | CSA, TUV, UL |
Weight | 0.882 lb (400.07 g) |
Frame Dimensions - mm 120 mm L x 38 mm W x 120 mm H
Operating Supply Voltage 24 VDC
Airflow 260.41 CFM
Speed 6000 RPM
Pressure Type 35 mmAq
Noise 64 dBA
Housing Material Aluminum
Termination Style Wire Leads
Series 9SG Type
Height 120 mm
Length 120 mm
Size 120 mm
Width 38 mm
Brand Sanyo Denki
Current Type DC
Product Type DC Fans
Factory Pack Quantity 21
Subcategory Fans
Tradename San Ace 120
Part # Aliases 05W9557 3784370
Unit Weight 400 g
We can also provide the following models
9HV1548L3D01
9WP1448E101
9GA0648F1D001
9HV1205C0D013
9HV3648W50023
109BMC24K0016-1
9GA2024K002
9WL1712A60011
9GV0405D3013
9HV0324A50013
9CRA1212G001
9HV0612B10011
9GV1212W00011
9GV2024G1D01
9HV1724D5D001
9GV2005K0013
9GV1705W301
9HV0424H60021
9GA4724S60023
9GV0912S0D0013
9GV0605G5011
9GA0924S40023
9WL0812S1H011
9WP5724A5H0011
9GA1248L9D01
9WL0912E1H021
9WP1712D5D001
9WP0424H6D011
9HV0624W102
9HV0312D2011
9WP0612D1011
9HV1512H0002
9HV4724S9013
9HV5712F2D0011
9HV1724C5013
9WP0824A50011
9GA5712E30021
9BMC12S017-1
9L1412E502
9GV1248B5002
9GV1505B0D0013
9WV0612S5D0011
9HV0948L3013
9WP0848L4D001
9WP1212E5H011
9GV0348W302
9HV1448L0013
9GV0424M7002
9HV0448E102
9GV0448K70013
9WV0848M4HD01
9GA1305B5D01
9GV1524K0D013
9WP0924H50011
9GV0348K2002
9GA0848W1D011
9GV0648H4021
9HV1248G1011
9GV0812E7013
9LG0948G3002
9HV0312F102
9GA4705B5D01
9GV1205B1D011
9HV3648K9D01
9GV1348F40021
9GV1524A3013
9GA0524C202
9WL0448M4002
9GV4712A6013
9HV1312G5001
9GA1224C9002
9GV1724J1023
9LG0448E4002
9GA0624A3013
9WV5748S6H0011
9HV2012G60023
9WV1712M5H0011
9GA1224B5D001
9HV1205W902
9HV0548S2011
9GA1705J40013
9GA1512A3023
9HV4705W6D0011
9GA0348B4013
9HV0512F6D001
9HV1312W9002
9HV3624L0D013
9CRL0924J0D001
9HV1212A0D01
9HV3605M7D0011
9GA1712E0023
For more information,please contact us freely
Sanyo Denki Fan 9SG1224G1D01
People who bought this item also viewed
KAKU Fan KA2206HA2-2
Pelko Motors Fan R1238Y24BPCB1-7
Sanyo Denki Fan 109R0612S401
Sanyo Denki Fan 9GA0824P4J001
Sanyo Denki Fan 9WL0412P3J001
Sanyo Denki Fan 9GV0812P1G03
Nidec Fan TUDC24B4
Sanyo Denki Fan 109BD24HD2
SUNON Fan EG30030S1-C020-S9A
ADDA Fan AD0824XB-F79DS
Copeland Compressor 6SLW-250E
Convo VFD CDE300-4T0R7G/1R5P
COSEL Power Supply PBA150F-3R3-G
TRIAD Transformer TCT50-08E07AB
LEEMIN Filter TFX-1000-100
Danfoss Sight Glass SGR 014-0002
Beckhoff Module EL3112
TYCO Relay 3SBC1520A2
PANASONIC Capacitor 30KV 5000PF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TAICIN Overflow Valve JRB-G-03-1
JAMICON Fan JF0825H1HSAR
Hager Circuit Breaker A061G C10
INTERMOT Hydraulic Motor GHM6-400
Recent related posts
-
08/14/2020
How much do you know about water-cooled chillers A few steps let you know
What is the cooling method of the chiller? A water-cooled chiller is one of them. It has many names. Some people say it is a chiller or a chiller. No matter which type, it is the same machine.
-
12/12/2021
How to Add Encoder to Stepper Motor
When the current flows through the stator winding, the stator winding produces a vector magnetic field. The magnetic field will drive the rotor to rotate an angle, so that the direction of magnetic fields of the rotor is consistent with that of the stator.
-
03/16/2021
How to maintain the servo motor driver?
In order to prolong the lifespanof the servo system, you should pay attention to the following aspects. For the operating environment of the system, the temperature, humidity, dust, vibration and input voltage need to be considered. Please regularly clean the ventilation system of the numerical control device. Always check whether the cooling fans on the numerical control device are working properly. It should be inspected and cleaned every six months or a quarter depending on the environment of the workshop.
-
06/14/2020
Central Air Conditioning Maintenance: Basic Procedure for Chiller Failure Treatment
In order to ensure the safe, efficient and economical long-term normal operation of the chiller, it is very important to discover the hidden dangers of failures as early as possible during its use. Today, the editor of Service will give you an analysis o 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ
-
09/06/2020
How to choose an air compressor in the food industry
Compared with other production-oriented industries, food safety is more important in the food industry. When choosing an air compressor, choose oil-free air compressors, which are also screw type, in order to ensure product quality.
-
10/12/2023
How Long Does It Take to Make Ice Cubes? Answers to All Your Ice-Making Questions
Ice cubes are a convenient way to keep drinks cold, especially during the hot summer months. They are also used in cocktails, smoothies, and many other recipes. However, have you ever wondered how long it takes to make ice cubes?
-
06/14/2020
Screw compressor overhaul
Screw compressor overhaul Screw compressor overhaul, normal working condition of refrigeration system in operation: 1. The suction temperature of the compressor should be 5-15 ℃ higher than the evaporation temperature; 2. The discharge temperature 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱
-
11/12/2021
Basics of Industrial Control System and the Use of PLC
The components of industrial control system (ICS) can be roughly divided into two categories according to their location: control center equipment and remote site equipment.
-
08/17/2020
What are the hidden dangers of improper central air conditioning installation
The peak holiday season has come to an end, and the baton is perfectly taken over during the peak work season. After a busy day, the most hope is to return to the comfortable home and get a good night’s sleep.
-
06/14/2020
Screw refrigeration compressors are prone to these types of failures, have you ever encountered them
The compressor is a volumetric compressor. Since its use in 1934, it has a dominant position in small to large and medium-sized refrigeration systems due to its excellent performance