SCHMERSAL Relay SRB-NA-R-C 16-24V
People who bought this item also viewed
TOGAMI Relay TJ-125-3F
Riken Relay RAB-150N
SIEMENS Relay 3TK2824-1AL20
TRIAD Transformer F5-56
ABB Circuit Breaker 10142823
Togami Contactor CLK-20J
Ferraz Shawmut Fuse ATMR2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Recent related posts
-
01/08/2024
Cooling Tower Troubleshooting and Solutions
Cooling towers are commonly used equipment in industry, air conditioning and other fields, and are used to remove the large amounts of heat generated during the production process.
-
07/17/2020
refrigerating system
4.1 Pressure vessels and pipelines are often contacted by refrigeration and air-conditioning technicians;; components of various systems; for example, placing an R--22 refrigerant storage tank on the rear panel of a car with a common barrier; The hot summer sun can make the temperature of the steel pipe reach 110F; the total area of
-
09/05/2020
What are the reasons for excessive oil content in exhaust gas and how to deal with it
1) The screw oil level is too high. If the oil level is too high, the fluctuation of the liquid level in the oil and gas barrels during the operation of the unit will cause a large amount of gas to enter the oi
-
08/20/2020
Cold storage anti-corrosion and anti-frost coatings effectively solve the problem of frosting and corrosion
In the cold storage, when the dew point of the air is lowered by the cooling pipe surface, the moisture in the food and air will precipitate and condense on the pipe wall. If the pipe wall temperature is lower than 0°C, it will condense into a rain layer.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/15/2020
Causes and solutions of frequent start-up of central air-conditioning compressors
Causes and solutions of frequent start-up of central air-conditioning compressors Central air-conditioning compressor Air conditioner compressor frequent start fault solution We sometimes encounter frequent start-up of air conditioner compressor, s 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ը 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/08/2022
Types of DC Motors
According to the reversible principle of DC motors, DC motors are divided into DC motors and DC generators.
-
07/27/2020
Selection and comparison of compressors
1. Piston compressor (the work of the piston compressor is the continuous change of the working volume formed by the cylinder, the valve and the reciprocating piston in the cylinder).
-
09/08/2020
What are the application areas of air compressors
In which industries are air compressors popular? As a general-purpose equipment in the new era, air compressors are inseparable from any gas demand. Below, let's take a look at the application areas of air compressors!
-
07/05/2020
Hitachi Air Energy Heat Pump Compressor
Hitachi Air Energy Heat Pump Compressor The compressor does not start and has nothing to do with the four-way valve coil heating mode Why can't the compressor of the four-way valve of the air conditioner start up after changing the heating mode? The compressor does not start and has nothing to do with the four-way valve coil heating mode.