There is no price at present, you can Request a Quote
Phaseo Economic
product or component type
Safety and isolation transformer
rated power in VA
63 VA
input voltage
230 V AC phase to phase, terminal(s): L1-L2
230 V AC single phase, terminal(s): N-L1
output voltage
24 V AC
secondary winding
Single
protective cover
Without
ambient air temperature for operation
-20...40 Celsius degrees
Complementary input voltage limits
207...253 V
network frequency limits
47...63 Hz
input voltage tolerance
+/- 15 V
efficiency
82 %
power dissipation in W
13.8 W
voltage variation at nominal load
0,116 at 230 V
output sustained overvoltage
0,136 (no load, hot state)
voltage drop at rated load
<= 14.13 %
no load losses
5.7 W
short-circuit voltage
0,133
output protection type
Against overload, protection technology: external
Against overvoltage, protection technology: external
Against short-circuits, protection technology: external
connections - terminals
Screw type terminals for input ground connection, connection capacity: 1 x 2.5...1 x 4 mm^2 AWG 14...AWG 11
Screw type terminals for input connection, connection capacity: 4 x 2.5...4 x 4 mm^2 AWG 14...AWG 11
Screw type terminals for output connection, connection capacity: 2 x 2.5...2 x 4 mm^2 AWG 14...AWG 11
marking
CE
fixing mode
By 4 screws, screw(s) D = 5 mm on horizontal panel with derating to 90 %, operating position: horizontal
By 4 screws, screw(s) D = 5 mm on vertical panel
By 4 screws, screw(s) D = 5 mm on vertical panel, operating position: vertical
By clips (with mounting plate) on 35 mm symmetrical DIN rail
operating altitude
3000 m
electrical insulation class
Class B
width
79 mm
height
90 mm
depth
70 mm
product weight
1.14 kg
Environment product certifications
EAC
IP degree of protection
IP20
environmental characteristic
EMC conforming to EN 62041
Safety conforming to EN 61558-1
Safety conforming to EN 61558-2-6
ambient air temperature for storage
-40...80 Celsius degrees
relative humidity
0...95 % during operation
overvoltage category
Class I conforming to VDE 0106-1
dielectric strength
Between input and ground
Between output and ground
Between input and output
Schneider Transformer ABT7ESM006B
There is no price at present, you can Request a Quote
People who bought this item also viewed
Siemens Transformer 4AM4396-0EG60-OFS1
CHINT Transformer JBK5-250
Schneider Circuit Breaker A9F28325
AEG Contactor WCH-07M/ET
Ferraz Shawmut Fuse PC73UD95V11CTF
HONGFA Relay HFV16-24-H1ST-R
UniOhm Resistor 3W82K
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KITZ Actuator FA-5
Yaskawa Servo Drive SGDS-01A31AY566
WOONYOUNG Relay WY3H3C10Z4
TCS Oil Seal TC 9*30*8
Honeywell Sensor SDP8600-003
Recent related posts
-
07/27/2022
Working Principle of a Vane Pump
During a rotation cycle, the volume between adjacent vanes changes because of the rotor’s eccentric mounting position.
-
09/15/2020
76 special atmospheric pressure transmitter, positive and negative pressure sensor
Pressure sensor, pressure transmitter, weighing sensor, PLC programmable controller, instrumentation, electronic scale 76 special atmospheric pressure transmitter, positive and negative pressure sensor
-
06/14/2020
Newly installed air conditioner, it trips when plugged in, what's going on
Newly installed air conditioner, it trips when plugged in, what's going on This question is about the problems that occur when the newly purchased appliances are used for the first time.
-
06/14/2020
The reasons for the high temperature of the compressor discharge are
The reasons for the high temperature of the compressor discharge are (1) The clearance in the compressor cylinder is too large; (2) The suction and exhaust valves and piston ring of the compressor are damaged; (3) The compressor safety bypass valve 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
07/31/2023
Why is My Heat Pump Freezing up (Causes, Prevention, and Solutions)
Heat pumps are a popular choice for heating and cooling homes, especially in moderate climates. They work by transferring heat from one place to another, either from outside to inside the home during winter or from inside to outside during summer.
-
06/14/2020
Basic knowledge and role of refrigeration oil
The function and classification of refrigeration oil and the requirements of refrigeration equipment for refrigeration oil
-
09/09/2020
The relationship between air compressor power, pressure and volume flow
Air compressor terminology: What is the relationship between air compressor power, working pressure and volume flow? First, let's first understand the definition of the three.
-
07/29/2020
Adding fluoride to the air conditioner is tricky, don't be fooled!
remind<br></br> In the hot weather, many citizens have begun to use air conditioners to remind everyone to be careful not to be fooled by unnecessary "air conditioner filling
-
09/08/2021
How to Test a Wheel Speed Sensor?
The wheel speed sensor is used to test the wheel speed of a car. For modern vehicles, wheel speed is essential.
-
08/11/2020
How to maintain the lubrication system of the chiller
In the operation system of the chiller, more attention is paid to the refrigerant circulation system, the chilled water circulation system and the electrical control system of the refrigerator. The lubrication system is often overlooked. As everyone knows, this system is also very important to the chiller.