Type 2 Chamber positive displacement diaphragm
pump, self priming, capable of being run dry
Control Type Pressure switch
Max Recommended Temperature 60° C (140° F)
Priming Capabilities 4 feet (1.2 m) suction lift
Re-start Pressure Shut-off Pressure 35 PSI: 25 PSI ±5 PSI (±0.3 bar)
Shut-off Pressure 40 PSI: 30 PSI ±5 PSI (±0.3 bar)
Shut-offPressure 70 PSI: 56 PSI ±5 PSI (±0.3 bar)
Inlet/Outlet Ports 3/8" (10 mm) hose barb
Leads 18 AWG, 14" (35 cm) long with 2-Pin connector / Leads
Duty Cycle Intermittent
seaflo Diaphragm Pump SFDP2-010-040-21
People who bought this item also viewed
ARO Diaphragm Pump 6662A3-244-C
Iwaki Diaphragm Pump EHN-B11SH9R
SEKO Diaphragm Pump MS1A094C21B4080
Becker Vacuum Pump U4.100190
Iwaki Magnet Pump MD-20R-220N
PROCON Water Pump 111S100F
EBARA Mechanical Seal EVM7.5KW
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PARKER Filter FC1091Q020BS
Mitsubishi Compressor NHJHV-5
Danfoss Solenoid Coil BE024AS
Recent related posts
-
09/05/2020
What are the reasons for excessive oil content in exhaust gas and how to deal with it
1) The screw oil level is too high. If the oil level is too high, the fluctuation of the liquid level in the oil and gas barrels during the operation of the unit will cause a large amount of gas to enter the oi
-
06/26/2020
Analysis of common faults and solutions of air-conditioning compressors
The air conditioning compressor is the heart of the refrigeration system and the power source for the refrigerant to circulate in the system. The basic working principle of the refrigeration system mainly includes the four processes of compression, condensation, throttling and evaporation.
-
09/20/2022
How Does a Hydraulic Pump Work?
In modern construction machinery, hydraulic working devices are basically inseparable.
-
03/06/2023
Types of Cylinder Seals and Factors Affecting Sealing Performance
Cylinder sealing is an important parameter to characterize the technical condition of engine. Cylinder sealing is related to the technical condition of cylinder block, cylinder head, cylinder gasket, piston, piston ring, inlet and exhaust valves and other parts.
-
08/09/2020
How to deal with the refrigerant leakage of precision air conditioner in computer room
As we all know, the power density of equipment in the computer room is high, so the volume heat is high. The computer room for exchange and data still needs to be continuously cooled by air-conditioning compressors to meet the environmental temperature requirements of communication equipment.
-
06/22/2020
What's the matter with air conditioning and cooling without heating
What's the matter with air conditioning and cooling without heating 1.First, it may be because the vents of the indoor unit and outdoor unit are blocked by something, or a lot of dust has accumulated on the filter inside the air conditioner; 2. It may be because the heat blown from the air conditioner is seriously lost; 3 2. It may be because the amount of refrigerant in the air conditioner is too small, which leads to a great reduction in the heat exchange efficiency, so that the air conditioner does not heat. <img src="{{media url="magefan_blog/What_s_the_matter_with_air_conditioning_and_cooling_without_heating3.jpg"}}" alt="" />
-
08/13/2020
How to choose the internal machine for cold storage Choose air cooler or exhaust pipe
Most of the cold storages we make are divided into many types, such as high temperature storage, low temperature storage, ultra low temperature storage, etc. So how to choose the internal machine of the cold storage?
-
06/09/2022
How to Test Solenoid Coil?
When selecting and using solenoid coils, we should think about the inspection and measurement of the coils, and then judge the quality and advantages and disadvantages of them.
-
06/30/2020
What happens if the refrigerant recovery time of the air-conditioning compressor is too long
What happens if the refrigerant recovery time of the air-conditioning compressor is too long At ordinary times, we will need to simply disassemble and assemble the compressor due to certain circumstances. However, if you do not pay attention to certain matters when disassembling, it will cause the compressor to be directly damaged, so you will not be able to compensate for it.
-
01/22/2023
How to Deal with Spindle Amplifier Alarm Codes?
When faults occur, there will be various alarm codes on the Spindle amplifier, each representing different faults.