Rated current(A): 10
Shihlin Circuit Breaker BHL22 C10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1021-1JA15
Fuji Circuit Breaker BW32SAG-2P005
Fuji Circuit Breaker BW32AAG-2P005
Fuji Circuit Breaker EW63EAG-3P060
CHINT Transformer TDR-320
Schneider Contactor LC2K1201E7
LINDNER Fuse NH2-400A
PHOENIX Relay 2903297
IRC Resistor 2W 35.3K
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Furnan Vane Pump 50T-17-FR+PA-1
REGO Safety Valve A2141A16
CARLO Relay DPA51CM44B011
VTOZ Overflow Valve WHR-012
Omron Switch D2SW-P01-2M
Dwyer Pressure Gauge DCGII-100
Recent related posts
-
06/25/2020
How to Hitachi Central Air Conditioning Compressor Maintenance Hitachi Central Air Conditioning Compressor【Detailed Explanation】
Hitachi central air-conditioning is a brand with good reputation and brand culture among central air-conditioning brands.The most indispensable thing for Hitachi central air-conditioning is Hitachi central air-conditioning compressor.If there is Hitachi central air-conditioning compressor, Hitachi central air-conditioning In order to work better, so for Hitachi central air-conditioning compressors, product maintenance of Hitachi central air-conditioning compressors is very important. The following editors will introduce to you-Hitachi central air-conditioning compressor product functions and maintenance.
-
02/21/2024
HVAC Blowing Cold Air in Winter: Reasons & Ways to Fix
Winter is upon us, and there's nothing more uncomfortable than expecting your HVAC system to provide a warm refuge from the cold, only to find it blowing cold air. This unexpected issue can leave homeowners frustrated and chilly.
-
01/09/2021
Commercial Refrigeration Compressor Market to Surge at 221.7 Million units by 2026; Introduction of Advanced Technologies to promote Growth, Says Fortune Business Insights™
Commercial Refrigeration Compressor Market to Surge at 221.7 Million units by 2026; Introduction of Advanced Technologies to promote Growth, Says Fortune Business Insights™ Key Companies Covered in Commercial Refrigeration Compressor Market Research Repo 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ
-
07/05/2020
Hitachi water source heat pump compressor
How does the air conditioning compressor work? The air-conditioning compressor is also called a rotary (rotor) compressor, and its working principle is to rely on an eccentric rotor under the action of spring force, the compressor, and the eccentric rotor are always in contact with the container separated by the sliding container Changes to achieve a process of compression. When the eccentric rotor rotates, the volume of the container changes and the gas is compressed.
-
09/14/2020
Technical standards for silent oil-free air compressors
Technical standard for silent oil-free air compressor 1. Subject content and scope of use 1. This standard specifies the terminology, technical requirements, test methods and inspection rules of silent oil-free air compressors.
-
03/29/2023
How to Choose the Right Refrigerator Compressor
The refrigerator compressor is the heart and the core component of a refrigerator. If the fridge compressor doesn't work, the whole fridge won't work either.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
12/24/2023
Why is Your Outside AC Unit Fan Not Running but Inside is? Troubleshooting and Solutions
As the sweltering summer heat bears down upon us, air conditioning becomes a vital necessity for maintaining comfort and sanity.
-
07/02/2020
okmarts.com platform compressor technology experts tell you why the air conditioner can be cooled
okmarts.com platform compressor technology experts tell you why the air conditioner can be cooled In the summer, I believe that many people's feelings must be hot, scorching heat, sweating, etc. At this time, air conditioning is naturally essential equipment. If the air conditioner in your home is not cooling, then the air conditioner becomes a decoration.
-
08/24/2020
Air conditioning cleaning service ushered in new air outlet
The weather is getting hot and the air conditioner cannot be turned on? Especially how to use central air conditioners in office buildings, shopping malls, enterprises and public places? What preparations should be made before turning on the air conditioners?