Rated current(A): 5
Pole number: 2
Fuji Circuit Breaker BW32AAG-2P005
People who bought this item also viewed
ABB Circuit Breaker GSH202 AC-C16
Fuji Circuit Breaker EW32EAG-3P010
Fuji Circuit Breaker EW100EAG-3P060
Fuji Circuit Breaker CP30FM-1P002
Fuji Circuit Breaker BW50RAGU-3P015
Siemens Circuit Breaker 3RV1011-1JA10
Siemens Circuit Breaker 3RV1021-4AA15
TRIAD Transformer VPP10-5600
Schneider Contactor LC1E95F5N
Ferraz Shawmut Fuse PC44UD70V30CP1
Nais Relay JJM1-9V
UniOhm Resistor 3W68K
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SUNON Fan PSD4812PMBX-A
HETE Tool for Metal Cutting 45° 12R1
Sanyo Compressor C-SBR145H16P
Recent related posts
-
08/19/2020
What is an air conditioner pressure sensor
The pressure sensor is a device that is installed on the pipeline of the outdoor unit of the air conditioner to perform pressure detection. The pressure detection result is transmitted to the computer board to control other parts of the air conditioner.
-
09/05/2020
The role of air compressor air filter and the hazards of overdue use
The air compressor air filter (also known as style) is composed of an air filter assembly and a filter element. The outside is connected to the air compressor's intake valve through a joint and a threaded tube to filter the dust, particles and other impurities in the air.
-
03/15/2021
FANUC FANUC spindle drive fault diagnosis
The motor does not rotate or the speed is abnormal After starting the spindle drive system, if the main motor does not rotate or the speed is abnormal, the possible causes are as follows
-
07/29/2020
Briefly talk about scroll, screw, piston, centrifugal refrigeration compressor Piston refrigeration compressor
Piston refrigeration compressor<br></br> Piston type (ie, reciprocating) refrigeration compressors are widely used, but the displacement is not large. Generally, they are small and medium-sized compressors. The cooling capacity of general air-conditioning conditions is less than 300kW.
-
07/06/2022
Proportional Valve Types for Different Applications
When it comes to Proportional Valves, they are well-suited to a number of different applications in machinery, basic processes and hydro-pneumatic systems.
-
08/21/2020
A newly installed air conditioner trips as soon as it is plugged in. What's the matter
This question is about the first use of newly purchased appliances. This question actually asks two questions: First, the newly installed air conditioner trips as soon as it is plugged in. Why?
-
12/28/2022
Advantages and Disadvantages of the PLC
The programmable logic controller (PLC) is a digital operating electronic system specially designed for application in industrial environment.
-
08/02/2020
How to use refrigerant to empty the air conditioner after installation
Air, moisture and impurities contained in the air will cause pressure increase, current increase, noise increase, and power consumption increase in the air conditioner system, which will reduce the cooling (heat) capacity, and may also cause ice blockage and dirty blockage.
-
11/23/2022
Classification of Flame Detectors
Burning generates smoke and releases heat, thanks to which, smoke detectors are invented to protect the people and properties.
-
09/29/2023
Heat Pump Clothes Dryer: Everything You Need to Know
Clothes dryers are a convenient appliance that saves time and effort when it comes to doing laundry. However, traditional clothes dryers can be not very energy-efficient.