| Type | 3RV1 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 75 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 57...75 A |
| Suitable for induction motors with P | 37 kW |
| Instantaneous overcurrent releases | 975 A |
| Short-circuit breaking capacity | 50 kA |
| Weight approx. | 2.253 kg |
Circuit breaker size S3 for motor protection, Class 10 A-release
57...75 A Short-circuit release 975 A Screw terminal Standard
switching capacity !!! Phased-out product !!! Successor is SIRIUS
3RV2 Preferred successor type is >>3RV2031-4KA10<<
product brand name SIRIUS
product designation circuit breaker
design of the product for motor protection
General technical data
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 38 W
at AC in hot operating state per pole 12.7 W
surge voltage resistance rated value 6 000 V
protection class IP
on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 50 000
continuous current rated value 75 A
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
57 ... 75 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating current
at AC-3
at 400 V rated value 75 A
operating power
at AC-3
at 400 V rated value 37 kW
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 50 kA
at AC at 500 V rated value 8 kA
at AC at 690 V rated value 5 kA
Short-circuit protection
design of the overcurrent release and short-circuit
release
thermomagnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 50022
height 165 mm
width 70 mm
depth 174 mm
required spacing
with side-by-side mounting
backwards 0 mm
at the side 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals with box terminals
for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
front side
type of connectable conductor cross-sections
for main contacts
solid 2x (2.5 ... 16 mm?)
stranded 2x (10 ... 50 mm?), 1x (10 ... 70 mm?)
finely stranded with core end processing 2x (2.5 ... 35 mm?), 2.5 ... 50 mm?
at AWG conductors for main contacts 2x (10 ... 1), 1x (10 ... 2)
Ask questions
(0/1,200)
- Q: Do you offer price matching if I find a lower price elsewhere?
A: We strive to offer competitive prices to our customers. If you find a lower price for the same product elsewhere, please contact our customer service with the details, and we will review your request on a case-by-case basis.
- Q: How can I provide feedback or review a product?
A: You can provide feedback or review a product by accessing the product page and clicking on the "Write a Review" or "Leave Feedback" option. Share your experience and opinions to help other shoppers make informed decisions.
- Q: Are my personal details shared with third parties?
A: We prioritize the privacy and security of your personal information. We do not share your details with third parties without your consent, except in cases where it is necessary for order fulfillment or as required by law.
Reviews
- W
William Kiger
Aug 14, 2025
Siemens Circuit Breaker 3RV1041-4KA15Your site has saved me so much time and effort.HelpfulUnhelpful - A
Al Moore
Mar 08, 2025
Siemens Circuit Breaker 3RV1041-4KA15The website is really easy to use and navigate.HelpfulUnhelpful - M
Mauricio Silva
Dec 10, 2024
Siemens Circuit Breaker 3RV1041-4KA15That's great, overnight shipping would be amazing!HelpfulUnhelpful - B
Bharat Patel
Nov 03, 2024
Siemens Circuit Breaker 3RV1041-4KA15Perfect, thanks for the great quality.HelpfulUnhelpful - B
Bob Manetta
Sep 21, 2024
Siemens Circuit Breaker 3RV1041-4KA15It's been a truly unforgettable experience.HelpfulUnhelpful - R
Ryan Elliott
Aug 02, 2024
Siemens Circuit Breaker 3RV1041-4KA15Excelente y rápidoHelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV1041-4KA15All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV1041-4KA15
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
ABB Circuit Breaker GSH202 AC-C16
Siemens Circuit Breaker 3RV1011-1AA10
Siemens Circuit Breaker 3WT8080-4UG04-5AB1
Siemens Circuit Breaker 5SN4463-7CN
Siemens Circuit Breaker 3WT8060-6UG00-0AA1
Siemens Circuit Breaker 3WT8080-6UG00-0AA1
Fuji Circuit Breaker EW50EAG-3P050
CHINT Transformer QZB-J-400
Lovato Contactor BF1810A400
DAITO Fuse PL3100
TYCO Relay V23154N 4734F104
Siemens Resistor A5E00171377
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Dungs Combustion Controller W- FM25 V2.0
HAWE Check Valve HRP 3V
Copeland Compressor ZP36K5E-TFR-275
EUTECH Conductivity Meter CON2700
NACHI Bearing NF 2278
Samsung Air Conditioner KFR-35GW-EPA2
Nidec Fan C34735-68
Ebmpapst Fan R2E250-AT06-19