| Type | 3RV2 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 0.16 |
| Number of Poles | 2 pole |
| Setting range for thermal overload releases | 0.11...0.16 A |
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.11...0.16 A N-release 2.1 A Spring-type terminal Standard
switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 ... +60 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
0.11 ... 0.16 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 0.16 A
operating current
at AC-3
at 400 V rated value 0.16 A
operating power
at AC-3
at 230 V rated value 20 W
at 400 V rated value 40 W
at 500 V rated value 60 W
at 690 V rated value 60 W
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 2.1 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.16 A
at 600 V rated value 0.16 A
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 106 mm
width 45 mm
depth 97 mm
required spacing
for grounded parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 400 V
downwards 30 mm upwards 30 mm
at the side 9 mm
for grounded parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
for live parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit spring-loaded terminals
arrangement of electrical connectors for main current
circuit
Top and bottom
type of connectable conductor cross-sections
for main contacts
single or multi-stranded 2x (0,5 ... 4 mm?)
finely stranded with core end processing 2x (0.5 ... 2.5 mm?)
finely stranded without core end
processing
2x (0.5 ... 2.5 mm?) at AWG conductors for main contacts 2x (20 ... 12)
design of screwdriver shaft Diameter 3 mm
size of the screwdriver tip 3,0 x 0,5 mm
Safety related data
B10 value
with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
with low demand rate acc. to SN 31920 50 %
with high demand rate acc. to SN 31920 50 %
failure rate FIT
with low demand rate acc. to SN 31920 50 FIT
T1 value for proof test interval or service life acc. to
IEC 61508
10 y
display version
for switching status Handle
Ask questions
(0/1,200)
- Q: Can I change the shipping address after placing an order?
A: We understand that sometimes you may need to change the shipping address. Please contact our customer service as soon as possible, and we will do our best to accommodate your request, depending on the order status and feasibility.
- Q: Is my personal information secure when shopping on your platform?
A: Absolutely! We take the security and privacy of your personal information seriously. Our platform utilizes advanced encryption and security measures to protect your data, ensuring a safe and secure shopping experience.
- Q: Are there any restrictions on using multiple discount codes for a single order?
A: The use of multiple discount codes for a single order may be subject to certain restrictions. Please refer to the terms and conditions of the discount codes or contact our customer service team for more information.
Reviews
- J
James Posey
Jul 18, 2025
Siemens Circuit Breaker 3RV2011-0AA20Exactly what I wanted, shipped promptly and professionally.HelpfulUnhelpful - T
Timmy Tran
Jul 02, 2025
Siemens Circuit Breaker 3RV2011-0AA20The shipment was delivered in a timely and professional way.HelpfulUnhelpful - N
Nathan Eyer
Feb 12, 2025
Siemens Circuit Breaker 3RV2011-0AA20That was so awesome, thanks for the lifetime memories!HelpfulUnhelpful - J
Jeff Novia
Jan 01, 2025
Siemens Circuit Breaker 3RV2011-0AA20It was completed with great efficiency.HelpfulUnhelpful - M
Michael F Harris
Dec 01, 2024
Siemens Circuit Breaker 3RV2011-0AA20I'm really grateful for this fantastic item that I've been longing for.HelpfulUnhelpful - Z
Zane Tidwell
Nov 29, 2024
Siemens Circuit Breaker 3RV2011-0AA20Tenían la pieza que necesitaba en buen estado y llegó a tiempoHelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV2011-0AA20All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV2011-0AA20
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
Siemens Circuit Breaker 5SY7613-7CC
Siemens Circuit Breaker 3WT8060-8UG04-5AB1
Siemens Circuit Breaker 3VF6111-6EL77-0AN1
Siemens Circuit Breaker 3VT8563-2EA04-0AA0
Terasaki Circuit Breaker PS250-GJ
AEG Circuit Breaker ME82S-C0.5
Honeywell Circuit Breaker GCP-33ANM7AAX
CHINT Transformer JBK4-800
Nader Contactor NDC2J-32/30
Ferraz Shawmut Fuse PC44UD60V40CTQ
NEC Relay EA2-24TNU
Yageo Resistor RC0603FR-071ML
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Shengkwei FAN SK205AP-11-1
Trafag Transmitter 8283.G4.2331.35
Copeland Compressor ZR125KCE-TFR-250
SOG Oil Seal TC110*130*10
Sanyo Denki Fan 109R0812H4D16
Tecumseh Compressor RK5512Y-AA3A