Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.8 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.55...0.8 A |
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.55...0.8 A N-release 10 A screw terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
height 97 mm
width 45 mm
depth 97 mm
Siemens Circuit Breaker 3RV2011-0HA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV2021-0JA10
Siemens Circuit Breaker 3RV1021-0GA10
Siemens Circuit Breaker 3RV1011-0CA15
Siemens Circuit Breaker 3RV1021-0JA10
Terasaki Circuit Breaker S400-GE
Siemens Circuit Breaker 5SY6116-7CC
Fuji Circuit Breaker CP30FM-2P003
Fuji Circuit Breaker EW63EAG-3P060
TRIAD Transformer F-236Z
Siemens Contactor 3RT2018-2AK61
Raychem Fuse RGEF500
Honeywell Relay GRH-4C-AC380V
UniOhm Resistor 0402WGJ0681TCE
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AUTONICS Relay SRS1-B1202R-2
EMERSON Check Valve ACK-10
TPC Air Cylinder AJGA50-50Y-W2PL
Recent related posts
-
06/29/2022
4 Common Failure of Piston Pump
There are several common modes of failure for variable displacement piston pumps. Understanding these modes of failure, the causes, warning signs, and the prophylactic means of monitoring will help you to reduce unscheduled downtime.
-
08/15/2020
How to correctly remove the ammonia refrigerant when repairing refrigeration parts
In the process of maintenance of the refrigerator, if there is a fault in the system components from the compressor exhaust shut-off valve to the accumulator outlet valve
-
07/19/2020
Have you mastered the general troubleshooting methods for ammonia refrigeration
In the refrigeration system of the cold storage, the refrigeration compressor is the core equipment, usually called the refrigeration host. At present, piston refrigeration compressors are mostly used in small and medium-sized cold storage refrigeration systems. Due to the different refrigerants,
-
11/08/2023
Centrifugal Fan vs. Axial Fan: Understanding the Differences and Applications
Centrifugal fans and axial fans are two common types of fan systems used in various industries and applications.
-
08/19/2020
Application of large temperature difference cooling water system in industrial cooling system
In the industrial cooling system, in order to meet the process requirements, small flow materials need to be cooled with a large temperature difference (for example, a certain juice beverage needs to cool the material from 30°C to 5°C
-
06/13/2020
What is the working principle of the cooling plate Introduction to the working principle of the cooling plate【Detailed explanation】
With the continuous development of technology, refrigeration equipment such as air conditioners have played a great role in our production and life. Everyone knows that air conditioning can be used for cooling, but they don’t know much about the cooling f 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ
-
01/04/2022
Case Studies of TECO Servo Drive and Servo Motor
Model is complete. Type-JSDA is used with 8192 PPR encoder. The servo motor JDDE is complete with 50W~15KW models and used with 2500PPR encoder.
-
06/21/2020
Which refrigerator is better
The two cooling methods of the refrigerator are good. From the perspective of defrosting, the air-cooled refrigerator will perform better, because the air-cooled refrigerator uses forced air convection to cool the temperature. It reaches the expected temperature, and it is not easy to frost. The direct-cooled refrigerator absorbs heat by the evaporator to reduce the temperature, and it is easy to condense the frost.<img src="{{media url="magefan_blog/Which_refrigerator_is_better.jpg"}}" alt="" />
-
08/21/2020
Common problems and solutions for ice making machines
1. Common problems and solutions of ice maker 1. The compressor is working but not cooling. Reason: The refrigerant leaks or the two-way solenoid valve is damaged and it is not closed tightly.
-
12/06/2022
How to Maintain a Linear Guideway?
Linear guideways are precision transmissions and require careful maintenance in order to give full play to their functions and prolong their service life. The followings are tips for the maintenance of the liner guideway