Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 32 |
Number of Poles | 4 pole |
Setting range for thermal overload releases | 27...32 A |
Circuit breaker size S0 for motor protection, CLASS 10 A-release
27...32 A N-release 400 A ring cable lug connection Standard
switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S0
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 13.25?W
at AC in hot operating state per pole 4.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP00
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
27?...?32?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 32?A
operating current
at AC-3
at 400 V rated value 32?A
operating power
at AC-3
at 230 V rated value 7?500?W
at 400 V rated value 15?000?W
at 500 V rated value 18?500?W
at 690 V rated value 30?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 25?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 55?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 400?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 32?A
at 600 V rated value 32?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 2?hp
at 230 V rated value 5?hp
for three-phase AC motor
at 200/208 V rated value 7.5?hp
at 220/230 V rated value 10?hp
at 460/480 V rated value 20?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 400 V gL/gG 63 A
at 500 V gL/gG 63 A
at 690 V gL/gG 63 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 45?mm
depth 97?mm
Siemens Circuit Breaker 3RV2021-4EA40
People who bought this item also viewed
AEG Circuit Breaker MBS 25 0.63-1A
Siemens Circuit Breaker 3VU1340-1MF00
Siemens Circuit Breaker 3VU1340-1TL00
Siemens Circuit Breaker 3RV1021-4AA10
Siemens Circuit Breaker 3RV1011-1FA10
Siemens Circuit Breaker 3RV2011-0KA10
Siemens Circuit Breaker 3RV2011-0DA10
Siemens Circuit Breaker 3RV1011-1BA10
CHINT Transformer NDKG-300
Schneider Contactor LC1F1154P7
DAITO Fuse LM50
TYCO Relay 3SBH1151A2
UniOhm Resistor 1206W4F1800T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Amico Check Valve 385 DN80
Sanyo Denki Fan 109P0924H401
OMRON Relay G3PA-240BL-VD DC5-24
ARK Air Cylinder KAND-25-45-I-P-A
XET Tool for Metal Cutting Ф9X2.5
Recent related posts
-
07/31/2020
The weather is getting colder and you need to pay attention to these hidden dangers when using air conditioners!
Soon after the summer ends, it feels like a direct transition to winter. The weather began to cool down, and many families began to use air-conditioning and other heating equipment one after another.
-
06/14/2020
Brief introduction Principle and advantages and disadvantages of refrigeration piston compressor
Brief introduction Principle and advantages and disadvantages of refrigeration piston compressor Principle: Rely on the reciprocating motion of the piston to compress the gas in the cylinder. Usually through the crank connecting rod mechanism, the rotary 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ
-
10/26/2021
Use of Baumer Encoder HMG11 and HOG10 in Iron and Steel Smelting Industry
Inside the noisy iron and steel smelting workshop, sparks flare and machines roar, crane weighing hundreds of tons slowly moves blast furnaces filled with molten iron from one station to the next.
-
01/13/2021
Gas stove solenoid valve working principle and classification
In gas stoves, the working principle of the solenoid valve is to control the mechanical movement by controlling the current of the electromagnet. There is a closed cavity in the solenoid valve of the gas stove, and there are through holes in different po 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ٺ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
07/03/2020
Global Piston Compressor Market Insight Report 2020 – Ariel, Siemens, Atlas Copco, Kobelco, Burckhardt Compression, Ingersoll Rand
Reports Insights Portable Oil Free Air Compressor Market Overview 2020 – 2026 The rising technology in Portable Oil Free Air Compressor Market is also depicted in this research report. Factors that are boosting the growth of the market, and giving a positive push to thrive in the global market is explained in detail.
-
01/10/2022
Heat Pump Compressor Troubleshooting
There are various types of compressors used in the heat pump unit and the fully enclosed piston compressor is the most commonly used type. However, when it’s in winter, there most probably are faults of this type of compressor due to frequent heating operations.
-
09/18/2021
Analysis of Refrigerant Prices Rising
Refrigerant is a compound that usually exists in a liquid or gaseous state. It easily absorbs heat from the environment
-
08/09/2021
Top 10 Sensors Types for Industrial Internet of Things
The Industrial Internet of Things (IIoT) is a major trend in the processing and manufacturing industry.
-
06/14/2020
An article to understand the centrifugal compressor
With the rapid development of technology in my country's air compression industry, air compressors have greatly improved in structural layout and functional form. Centrifugal air compressors have become a new generation of air compression equipment. Since 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧҈ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理
-