Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 36 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 28...36 A |
Circuit breaker size S2 for motor protection, CLASS 10 A-release
28...36 A N-release 520 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 20?W
at AC in hot operating state per pole 6.7?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
28?...?36?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 36?A
operating current
at AC-3
at 400 V rated value 36?A
operating power
at AC-3
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 30?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 520?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 36?A
at 600 V rated value 36?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 125
at 500 V 100
at 690 V 80
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Siemens Circuit Breaker 3RV2031-4PA15
People who bought this item also viewed
Siemens Circuit Breaker 5SL6110-7CC
Siemens Circuit Breaker 3WN6381-0WA58-3KA3
Siemens Circuit Breaker 3RV1011-1EA10
Siemens Circuit Breaker 5SV3344-6
Siemens Circuit Breaker 3RV1011-0BA10
Mitsubishi Circuit Breaker NV100-SEP 50A
Siemens Circuit Breaker 3RV1042-4MA10
Terasaki Circuit Breaker XE50NS
Tamura Transformer MET-42
Shilin Contactor SD-P16 220V
Ferraz Shawmut Fuse PC30UD69V100D1A
CRYDOM Relay CMRD4855-10
UniOhm Resistor 0603WAJ0183T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Kompass Vane Pump VQ315-52-19-FR
Marcon Capacitor 80V 47000UF
VTOZ Overflow Valve WDKE-17119-P24DC
TECO PLC SG2-20KR-A
Sumitomo Gear Pump QT63-80
ROTEN Mechanical Seal 82-45G
Recent related posts
-
01/19/2022
Transmitter Common Faults & Diagnosis Methods
Transmitter faults mainly include complete fault, bias fault, shifting fault, and precision degradation fault. This is shown in figure 2.
-
09/15/2020
The working principle of air compressor
The air compressor is the main body of the air source device. It is a device that converts the mechanical energy of the prime mover (usually an electric motor) into gas pressure energy, and is a pressure generating device for compressed air.
-
01/03/2024
Printer Cooling: Methods, Common Problems & Troubleshooting
Printers are familiar to everyone and are one of the essential office tools for work. From inkjet, dot matrix, laser, to the now popular 3D technology, printers have developed rapidly.
-
07/17/2020
Reasonably adjust the cold storage evaporator and defrost in time
Reasonably adjust the cold storage evaporator and defrost in time Generally speaking, every increase in the cold storage evaporation temperature can save energy Therefore, under the premise of satisfying the low refrigeration process of the product, the evaporation temperature can be increased as much as possible by adjusting the amount of liquid supplied. The thermal resistance of the frost layer is generally much larger than the thermal resistance of the steel pipe.
-
07/26/2020
Why is the refrigeration compressor always overheating protection?
Compressor overheating protection means to protect the compressor motor from being burned. When the motor temperature or the compressor's own temperature exceeds a certain value, some built-in or external protection devices are used to disconnect the compressor's working power supply to achieve protection The role of the compressor.
-
08/14/2020
How much do you know about water-cooled chillers A few steps let you know
What is the cooling method of the chiller? A water-cooled chiller is one of them. It has many names. Some people say it is a chiller or a chiller. No matter which type, it is the same machine.
-
09/10/2020
Discussion on Reasons and Protection of Air Compressor Motor Damage
Air compressor is abbreviated as air compressor. As a general-purpose mechanical equipment, it is widely used in the field of industrial and agricultural production. The problem is that the motor (three-phase asynchronous motor) as the power equipment of the air compressor generally has a higher failure rate than other motors.
-
10/21/2023
Why Does My AC Keep Freezing Up at Night?
During the hot summer months, a well-functioning air conditioning (AC) system is crucial to maintaining a comfortable indoor environment. However, if your AC keeps freezing up at night, it can be a frustrating and perplexing problem.
-
06/27/2022
How to Test an Encoder with a Digital Multimeter
A basic multimeter can be utilized to measure the encoder’s parameters. Bear in mind that a digital multimeter can measure the average duty cycle, frequency, peak voltage, and average voltage of an encoder.
-
01/11/2021
[Case] Air conditioner compressor does not work after Mitsubishi Pajero overhaul Failure phenomenon:
[Case] Air conditioner compressor does not work after Mitsubishi Pajero overhaul Failure phenomenon: The Mitsubishi Pajero off-road vehicle uses a 6G72 engine. The air-conditioning compressor does not work after the car is overhauled and the condenser 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁