Operating distance: 2 mm
Operating voltage: 15-34 V DC
Output: NPN NO
Connection: Cable 2M
Siemens Sensor 3RG4012-0GB00-5AB8
People who bought this item also viewed
IFM Sensor PI2798
TAKEX Sensor GR12GN
Banner Sensor Q60VR3AF2000Q1
TAKEX Sensor GR02SPN
Endress Hauser Transmitter PMC71-ABA2C2GABAU
Honeywell Flame Detector C7915A1036
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
THK Linear Guideway SRS9MQZUU
Dwyer Transmitter 641-30
Recent related posts
-
06/14/2020
What is a refrigeration compressor and how does it work
What is a refrigeration compressor and the working principle of a refrigeration compressor A refrigeration compressor is the most important equipment in a refrigeration device, and is usually called the host in the refrigeration device. Refrigerant vapor ﰸ2 䀀 ᅵ皥
-
07/28/2020
Common faults and solutions of screw chillers
Low voltage overrun protection:<br></br> Solution: Replace or clean the filter element; clean the suction port filter.<br></br> Dirty or ice blockage at the inlet of the expansion valve:<br></br> Solution: Dirty blockage: remove the expansion valve and clean it. Ice blockage: replace the filter drier and run again
-
07/16/2020
How to see if the refrigerant leaks in the high and low temperature test chamber
How to check whether the refrigerant leaks in the high and low temperature test box; the standard high and low temperature test box and the constant temperature and humidity test box are all selected by the air-cooled compressor, and the working principle is the same as that of the air conditioning refrigeration
-
07/29/2020
6 possible reasons why the air conditioner is not cooling
6 possible reasons why the air conditioner is not cooling<br></br> The reasons why the air conditioner is not refrigerated are divided into non-air-conditioning faults and air-conditioning faults. Today we share the reasons for non-air-conditioning faults.
-
08/17/2020
Causes and solutions for high-pressure alarms of refrigerators
Generally, the refrigerator is equipped with a full set of protection devices. When the refrigerator has a high-pressure alarm, it will automatically start the protection device, and the corresponding fault indicator will light up
-
01/07/2021
Why does the air conditioner frost
Why does the air conditioner frost Q: Why does frost occur when the air conditioner is running? Answer: When the air conditioner is performing heat pump heating operation, the surface temperature of the heat exchanger of the outdoor unit will be very 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵
-
08/05/2021
2 Causes of Your Compressor Motor Failure
A compressor is a kind of driven fluid machinery that elevates low-pressure gas to high pressure. It is the heart of the refrigeration system.
-
01/19/2022
Transmitter Common Faults & Diagnosis Methods
Transmitter faults mainly include complete fault, bias fault, shifting fault, and precision degradation fault. This is shown in figure 2.
-
08/17/2020
What should I do if the compressor current of an industrial chiller is overloaded? okmarts.com editor has a coup!
The compressor current overload phenomenon of industrial chillers, cause analysis and solutions. The "overcurrent" here refers to the current overload of the chiller compressor.
-
10/18/2023
Dehumidifier Compressor Hot: Reasons and Fixes
A dehumidifier is an essential appliance for maintaining a comfortable and healthy indoor environment by reducing excessive humidity.