Port size:3/8"
Fluid:Air
Ambient and fluid temperature:-5 to 60℃(with no freezing)
Proof pressure:1.5MPa
Maximum operating pressure:1.0MPa
Minimum operating pressure:0.05MPa
Nominal filtration rating:0.3um
Outle side oli mist concentration:Max.1.0mg/m3(ANR)
Rated flow(L/min(ANR)):450
Drain capacity(cm3):25
Bow material:Polycarbonate
Bow guard:Standard
SMC Fuel Water Separator AFM30-03D-2-A
People who bought this item also viewed
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
DEKEMA Vane Pump PV2R2-75-FR
Sandpiper Diaphragm Pump S10B1P2PPAS000
Siemens Circuit Breaker 5SL4225-8CC
NACHI Vane Pump VDC-13A-1A3-1A4-20
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic Light Curtain SF2B-H12-P
CALPEDA Water Pump MXV 32-405
P+F Pepperl Fuchs Sensor NBB20-U1-A2
Johnson Controls Actuator M9206-GGA-4S
IFM Sensor I12001
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/21/2020
11 common protection devices for refrigeration compressors
When the compressor is running, some abnormal conditions may occur, such as: exhaust pressure is too high, suction pressure is too low, oil pressure is insufficient, motor is overheated, excess liquid enters the cylinder, etc. In the event of an abnormal situation, the compressor will be damaged if there is no protective measure.
-
12/25/2021
Japanese Giant Mitsubishi Heavy Industries Goes Into Central Air Conditioners for Home Use
In recent years, it’s probably difficult for people to choose between central air conditioners and split air conditioners for home use. In fact the time that central air conditioners are used for home refurbishing is not long yet.
-
01/02/2021
Mads Clausen - the founder of Danfoss
From just a single valve and an unquenchable desire to succeed, Danfoss founder, Mads Clausen, created a global business that still sets the standard for innovation today.
-
04/19/2023
4 Types of Safety Protection for Refrigeration Compressors (9 Common Protection Devices for Refrigeration Compressors)
When the compressor is running, some abnormal situations may occur, such as: the exhaust pressure is too high, the suction pressure is too low, the oil pressure is insufficient, the motor is overheated
-
09/03/2022
How to Choose a Contactor?
In industrial electricity, the contactor uses an energized coil to generate a magnetic field to close the contacts to control the load.
-
06/14/2020
How to properly maintain the refrigeration compressor
How to properly maintain the refrigeration compressor 1. Frequently check whether there are debris or even conductive objects in the motor, whether the coil is damaged, and whether the stator and rotor are rubbed, otherwise the motor will burn out after ﰸ2 䀀 ᅵ皥
-
09/05/2020
The problem of motor inefficiency
The test standards promulgated by the International Electrotechnical Commission IEC (hereinafter referred to as IEC) make it possible to evaluate the energy efficiency of motors.
-
06/14/2020
Refrigeration compressor maintenance guide
Refrigeration compressor maintenance guide The refrigeration compressor is the core and heart of the refrigeration system. The capacity and characteristics of the compressor lead to the capacity and characteristics of the refrigeration system. So how to 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵
-
09/14/2020
Application of synthetic compressor oil
At present, synthetic lubricants are widely used in the compressor field. Among them, oil-injected and oil-immersed rotary screw air compressors and large reciprocating compressors are one of the most used markets.