Connections:Gasket mount type
Nominal diameter: 1/4
Spool operating method: No-spring type (with detent)
Maximum operating pressure MPa {kgf/cm2}:35 {350}(25 {250}) *1
Maximum flow rate L/min:100
Permissible back pressure MPa {kgf/cm2}:17.5 {175}
Maximum switching frequency times/minute
AC, DC:240
With rectifier:120
With built-in surge killer
DIN connector type with lamp:100
External coating protection:IEC Pub529 IP65
Daikin Solenoid Valve C-KSO-G02-2DP-20
People who bought this item also viewed
CKD Solenoid Valve 4F430-08-AC100V
CKD Solenoid Valve 4GD219-06-E2C-3
Daikin Solenoid Valve KSO-G02-4CB-30-E
Daikin Solenoid Valve KSO-G03-2DP-30-EN
Daikin Solenoid Valve C-KSO-G02-20BA-30
Daikin Solenoid Valve KSO-G02-2CD-30
CHELIC Solenoid Valve SR-310-M5-DC24
AirTac Solenoid Valve 7V21008B
AirTac Solenoid Valve 7V12006B050
Danfoss Transmitter 060G6100
CHINT Transformer NDKS-100
Baumer Sensor OADM 20I5481/S14C
FESTO Check Valve HB-1/4-QS-8
TAICIN Vane Pump VF15-17-01
RIFA CapacitorPEG124PE2470Q
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HENGSTLER Encoder RI58-D/300EF.47IF
SMC Proportional Valve ITV1030-312L
Recent related posts
-
06/30/2020
Lubrication method for air conditioner compressor fault maintenance
Lubrication method for air conditioner compressor fault maintenance The specific conditions of the lubrication method for air conditioner compressor fault maintenance are as follows:
-
06/30/2020
What are the factors that cause motor damage?
What are the factors that cause motor damage? What are the factors that cause damage to the compressor motor: 1. Abnormal load and stall
-
09/21/2020
Lubricant knowledge
Lubricating oil knowledge 1. Lubricating oil function Lubricating oil is a liquid lubricant used on various types of machinery to reduce friction and protect machinery and processed parts. It mainly plays the role of lubrication, cooling, rust prevention, cleaning, sealing and buffering.
-
01/05/2021
Refrigerant, compressor, expansion valve (flow control device), evaporator, condenser, pipes and tubes.
Refrigerant, compressor, expansion valve (flow control device), evaporator, condenser, pipes and tubes. Skematic of Compression Refrigeration System
-
08/15/2020
Solution to the condensing pressure of the chiller refrigeration system
1. The condenser of the chiller is dirty Computer room chillers generally use air-cooled condensers, which are composed of multiple sets of coils, and fins are added to the coils to increase the heat transfer area on the air side.
-
01/07/2021
Today in the air-conditioning market is tomorrow for fresh air systems
Today in the air-conditioning market is tomorrow for fresh air systems Now we have a fresh air system for work and life, so that even if we are in a closed building environment, we can breathe fresh air. In fact, today's fresh air system has also gone 器2 䀀
-
08/27/2021
Why a Compressor is Used in the Refrigeration System
Why are refrigeration compressors used in small and medium-sized refrigeration systems? The compressor is the core equipment in the refrigeration system
-
07/27/2020
The heat is unbearable, and the car air conditioner is turned on like this to quickly cool down
It is the dog days right now. As the saying goes: "Small summer heat catches the big heat, so there is nowhere to hide." If the outdoor in summer is like a stove, then the car can definitely be regarded as an "alchemy stove".
-
07/17/2022
How to Repair Gear Pump
In the previous article, we introduced a lot about the gear pump, so how to install the gear pump? Let's talk about it today.
-
05/30/2022
What is Power Supply?
Power supply is a device that converts other forms of energy into electrical energy and provides electrical energy to circuits (electronic equipment).