TCS Oil Seal TC 35*78*10
People who bought this item also viewed
TCS Oil Seal TC 33*46*10
SKF Oil Seal 55X85X8 HMSA10 V(FKM)
TTO Oil Seal TC 115*150*12
SOG Oil Seal TB135*160*15
TTO Oil Seal TC 35*62*10
Repair Kit for Komatsu 6D95
SKF Mechanical Seal 3309 ATN9
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ORIX Fan MRS16-TTM-F1
TSUBAKI Belt BG153UP3M10-HC
Recent related posts
-
08/25/2020
Cold pipe refrigeration system only half the power of the air conditioner
On August 19, according to foreign media reports, a new study from the Proceedings of the National Academy of Sciences demonstrated a new energy-saving refrigeration system that only needs half the electricity of the air conditioner.
-
01/07/2021
Why does the air conditioner frost
Why does the air conditioner frost Q: Why does frost occur when the air conditioner is running? Answer: When the air conditioner is performing heat pump heating operation, the surface temperature of the heat exchanger of the outdoor unit will be very 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵
-
09/11/2020
Selection skills of single screw pump
The professional senior engineer of the air compressor construction machinery leasing company told everyone that the specification of the single screw pump is determined by the nature, flow and pressure of the liquid to be transported, and the speed of the pump is determined by the viscosity and corrosiveness of the liquid. The selection of parameters can ensure the reliable operation of the pump.
-
07/18/2020
The core heart of the chiller-compressor
Power compressor is indispensable when refrigeration equipment is cooling. Such as chillers, chromatography freezers, ice machines, ultra-low temperature refrigerators, etc., their driving force is the refrigeration compressor, the entire refrigerant cycle is the refrigeration compressor
-
06/14/2020
Top 3 Applications for a Servo Motor
Servo motors are essentially electric motors with inbuilt motor
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/11/2020
Development and Trend of my country's Frequency Converter Industry
With the rapid development of power electronics technology, computer technology and automatic control technology, electric drive technology is facing a historic revolution. AC drives have gradually become the mainstream of electric drives.
-
06/25/2020
Introduction of working principle and application of centrifugal refrigeration compressor for air conditioning
The principle of the air-conditioning compressor is to maintain the circulation of the refrigerant in the refrigeration system by means of external force. The air-conditioning compressor sucks in low-temperature, low-pressure refrigerant vapor from the evaporator.
-
07/10/2022
How to Replace Mechanical Seals in Centrifugal Pumps
Mechanical seals are used in centrifugal pumps to keep water or any liquid from making contact with the delicate parts of the machine.
-
07/03/2020
Research On Global Commercial Refrigeration Compressors Market (impact of COVID-19) with Top Players: Emerson,GMCC,Huayi Compressor,Huangshi Dongbei and Others
The Centrifugal Air Compressor Report is a specific investigation of the overall market. the item comprises of slanting innovation, showcase drivers, provincial tendencies, measurements, expectations, producers and merchants.