Long service life, long-term maintenance-free operation
Low dust generation, low noise,acceptable running sound
Smooth motion in all mounting orientations
Thin, compact design, large radial load capacity
Superb in planar running accuracy
Superb capability of absorbing mounting error
THK Linear Guideway HSR45A1QZSS
People who bought this item also viewed
SBC Linear Guideway SBS25HLL
THK Linear Guideway SHS20V1SS
THK Linear Guideway SHS25LV1UU
THK Linear Guideway HSR35LB1UU
THK Linear Guideway SHS30LV1UU
SBC Linear Guideway SBI25FL-K1-N
SBC Linear Guideway SBI45FLL-C-K1
SBC Linear Guideway SBI15SL-K1-N
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TYCO Relay V23057-B3006-A101
STAF Linear Guideway BGXH30FL
KOMPASS Check Valve CRG-10-A2
Schneider Circuit Breaker A9F17240
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/04/2020
The benefits of using precision filters
Compressed air purification requires the use of precision filters, which are very useful. Although there are many filter equipments nowadays, the precision filter is undoubtedly the most special one, and it is also a leader in the filter industry. What are the benefits of using precision filters?
-
07/27/2020
Content overview: compressor operating principle, A/C switch function, difference between internal and external circulation air intake system
The season of using cold air-conditioning is coming: how to use the A/C switch and the operating principle of the car air-conditioning system. These two points are necessary for car users to understand some knowledge; especially the switching method of internal and external circulation, in different modes The ability of air purification and filtration will vary greatly. Let's talk about the air conditioning system of a car.<br></br>
-
09/03/2020
The customer says the price is high, what should the air compressor seller do
After quoting customers, we often encounter such a problem, "Your price is too high". Strictly speaking, it is not a rejection of the question "your price is too high" raised by the customer. This is actually a positive signal.
-
07/18/2020
The common fault analysis of refrigeration compressors is here!
Working condition and adjustment of refrigeration system of low temperature chiller Refrigerators are now widely used in the refrigeration industry, and the refrigerant is usually R22 (also R404a). In order to facilitate operation and maintenance and reduce the installation location, the refrigeration compressor, oil separator, water-cooled shell and tube condenser, filter drier
-
12/30/2021
Air Conditioner Refrigerant Leakage & Solutions
An air conditioning refrigeration system is composed of a compressor, condenser, throttling valve, evaporator, and connecting copper pipe and many other parts and accessories.
-
03/01/2022
Factors Affecting Air Compressor Performance in Long-Period Operation
Through the research on the use and periodic failure factors of compressors in recent years, it is known that bearing clearance.
-
08/19/2020
Knowledge of two air conditioners the same and different between evaporator and condenser
Condenser and evaporator are heat exchangers, which are widely used in refrigeration systems of high and low temperature alternating damp heat test chambers, constant temperature and humidity test chambers and other equipment.
-
04/18/2022
How to Properly Ground The Electromagnetic Flowmeter Under Different Installation Conditions?
Because the output signal of the sensor is very small, it is usually only a few millivolts. In order to improve the anti-interference ability of the instrument, the zero potential in the input circuit must be grounded
-
09/03/2020
Air compressor application-spraying industry
Air spraying can be said to be a spraying method with convenient operation, easy color change, high production efficiency, good atomization effect, and high-quality surface with fine rust.