16A Miniature Power PC Board Relay
Meet UL 508, VDE0435 and SEMKO requirements
OMIH = 16A rating
TYCO Relay OMIH-SS-105LM,300
People who bought this item also viewed
SIEMENS Relay 3TK2824-1AL20
Riken Relay RAB-150N
JEL Relay S1C-225WDV
Tamura Transformer PL20-12-130B
Eaton Contactor DILM95-22
Littelfuse Fuse 0215012.MXEP
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CARLO Relay RGC1A60D92GGEP
THK Linear Guideway SRN45CSR
PALL Filter FR1L620EH
Eaton Moeller Circuit Breaker LZMB2-A160
Recent related posts
-
09/15/2020
Matching selection for small internal compression process design
As a traditional process type, small internal compression process equipment has been produced in the okmarts.com factory for many years. It is well received by users for its inherent advantages.
-
06/22/2020
Make home life easy for a summer
Refrigerators, I believe that every household has its figure, which guarantees the freshness of the food and brings a hint of coolness on the hot summer day. The core component of the refrigerator is the compressor. How does the refrigerator compressor work? Today, let's take a look at the relevant introduction of refrigerator compressor!
-
09/11/2020
Energy saving China's big idea
From global emission reduction actions to the fashionable low-carbon economy, from smart grids from models to new energy vehicles, the human economic growth model in the era of transformation is undergoing a gorgeous and tempting turn. . Under the background of this magnanimous background, China Energy Conservation's long-term planning and specific actions have been given strong and vivid connotations.
-
06/13/2020
This is the reason for the overheating of refrigeration compressor exhaust~!
This is the reason for the overheating of refrigeration compressor exhaust~! The main reasons for the exhaust temperature overheating are as follows: high return air temperature, large motor heating capacity, high compression ratio, high condensation pre 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁
-
09/07/2020
What happens if the water-cooled air compressor is short of water
The cooling methods of screw air compressors are mainly divided into two types: air-cooled and water-cooled. Air-cooled air compressors are a relatively common cooling method and are used in small and medium-sized air compressors.
-
07/19/2020
The role of precision chillers in various industries
In the precision chiller, the heat absorbed from the evaporator and refrigeration compressor and in the pipeline is transferred to the surrounding medium to take away, and the refrigerant high-pressure superheated vapor recondenses into a liquid. In the cooling process of the chiller, the condenser plays a role in outputting heat energy and condensing the refrigeran
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
03/01/2021
Related technical terms
1.Positioning or residual torque: when there is no current passing through the winding, the torque required to make the output shaft of the motor rotate. 2.Driver: an electrical control device used to run the stepping motor. This includes power supply, logic programmer, switching element and a variable frequency pulse source which determines the step rate. 3.Dynamic torque: the torque produced by the motor at a certain step rate. The dynamic torque can be expressed by PULL IN torque or PULL OUT torque.
-
09/10/2020
Discussion on Reasons and Protection of Air Compressor Motor Damage
Air compressor is abbreviated as air compressor. As a general-purpose mechanical equipment, it is widely used in the field of industrial and agricultural production. The problem is that the motor (three-phase asynchronous motor) as the power equipment of the air compressor generally has a higher failure rate than other motors.
-
08/11/2020
How to choose a dedicated central air conditioner in a supermarket
Everyone should be familiar with central air-conditioning. It is widely used in our homes and some public places. It can adjust the temperature in the house very well and can bring good ventilation effects.