VALUE Vacuum Pump VRD-8
Type: Vacuum Pump
Brand: VALUE
Displacement speed: 8/9.6(50/60Hz) m3/h ; Ultimate total pressure gas ballast close: 5*10-1 Pa ; Ultimate total pressure gas ballast open: 3 Pa ; Rotation speed: 1440/1720(50/60Hz)
Type: Vacuum Pump
Brand: VALUE
Type: Vacuum Pump
Brand: VALUE
NASH Vacuum Pump 2BV2070ONC002P
NASH Vacuum Pump 2BV2061ONC022P
Kuobao Magnet Pump MPX-F-441CCV5
PULSAFEEDER Diaphragm Pump WS-03-07-S
YOTEC Water Pump 65-200
EBARA Mechanical Seal 3S40-160/4.0
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CHANTO Air Cylinder ASR150X100
DENISON Piston Pump PV29 2R1D F02
Siemens PLC 6ES7315-2FJ14-0AB0
07/13/2022
Air compressors can be used to power all kinds of pneumatic tools, such as nail guns and other handy tools you might find yourself using to get construction and building projects done more quickly.
08/03/2023
Heat pumps are an incredibly effective way to regulate indoor temperatures throughout the year. During the summer months, they work to cool your home by extracting heat from the indoors and dispersing it outside.
07/31/2020
The cost of cold storage with a refrigeration capacity of less than 60kw is relatively large. It is generally suitable for small cold storage and air conditioning units. The cost of such small cold storage within 100 square meters ranges from 30,000 to 100,000.
08/31/2023
Are you considering a new heating and cooling system for your home or office? Have you heard about ducted heat pumps, but aren't sure what they are or how they work? If so, this article is for you.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
05/30/2022
Testing a power supply is an important step when troubleshooting many issues, most obviously when your computer is having trouble starting.
06/14/2020
The compression ratio of the screw machine is too large: it proves that this system completely deviates from the design value. The main phenomena are that the temperature of the exhaust temperature is too high, the suction pressure is too low, and the tem 器2 䀀 ᅵ皥
07/16/2020
1. The pressure of the scroll compressor is generated due to the interaction between the scroll disks that make planetary motion. When one of the scroll disks makes planetary motion, the gas enters from the outer opening.
09/15/2020
With the vigorous development of the instrumentation industry, miniature vacuum pumps and miniature air pumps that are compact, oil-free and environmentally friendly have become more and more widely used. How can we choose the most appropriate product among a wide range of micropumps?
09/06/2020
What is PID regulation and the basic knowledge of PID At present, the level of industrial automation has become an important indicator of the modernization level of various industries.