08/07/2020
What should I do if the refrigeration compressor returns oil
During the operation of the system, the lubricating oil is discharged from the compressor along with the refrigerant, and returns to the compressor after the cycle.
-
09/07/2020
Commonly used energy saving points for air compressors
Air compressors are recognized as energy-intensive process equipment, and screw compressors are no exception. However, in the daily operation process, the energy consumption of screw compressors often does not attract enough attention from operating units. The main reason:
-
06/28/2020
One article to understand what is a piston compressor
One article to understand what is a piston compressor Piston compressor is a compressor that relies on live cold reciprocating motion to pressurize gas and deliver gas. It belongs to positive displacement compressor, also known as "reciprocating piston compressor" or "reciprocating compressor".
-
06/14/2020
11 common protection devices for refrigeration compressors
11 common protection devices for refrigeration compressors When the compressor is running, some abnormal conditions may occur, such as: the discharge pressure is too high
-
08/20/2020
How to maximize energy saving of industrial chillers
1. Industrial water chillers prevent and reduce pipeline fouling to improve the heat exchange efficiency of condensers and evaporators. If water treatment is not done well, calcium
-
08/17/2020
Analysis of 4 major reasons for the high energy consumption of building HVAC systems
1. Analysis of the high energy consumption of the building HVAC system The reasons for the high energy consumption of building HVAC systems are mainly reflected in the following aspects:
-
06/14/2020
Problems and case analysis of electronic expansion valve and four-way valve
Problems and case analysis of electronic expansion valve and four-way valve 1. The problem of electronic expansion valve 1 Identify the quality of electronic expansion valve: Step one (see): Whether the wiring is plugged in place and whether the c 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧զ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
02/06/2022
Why Refrigeration Compressor not Work but Operate Normally
In some cases, you would find that the compressor motor starts and runs normally, but it cannot compress the refrigerant.
-
07/18/2020
The advantages and disadvantages of screw refrigeration compressor
Power compressor is indispensable when refrigeration equipment is cooling. Such as chillers, chromatography freezers, ice machines, ultra-low temperature refrigerators, etc., their driving force is the refrigeration compressor, the entire refrigerant cycle is the refrigeration compressor
-
07/23/2020
Analysis of Overheating Failure of Refrigeration Compressor
The main reasons for the overheating of exhaust temperature are as follows: high return air temperature, large heating capacity of the motor, high compression ratio, high condensation pressure, and improper refrigerant selection.<br></br> <br></br>