Performance specification: High Performance
Valve size: D08
Maximum flow rate: 700 L/min
Maximum operating pressure: 5076 psi
Coil voltage: 24 V dc
Spool/spring arrangement: Spring centered
Vickers Solenoid Valve DG5V-8-H-8C-E-VM-U-H-10
People who bought this item also viewed
Vickers Solenoid Valve SV3-12-0P-0-00
Vickers Solenoid Valve SV3-16-0-0-24DG
Vickers Solenoid Valve MRV3-10-D-0
Daikin Solenoid Valve C-KSO-G03-7CB-20
KOGANEI Solenoid Valve V200E1-2-L-SR
MAC Solenoid Valve 167B-121JB
Tecumseh Compressor AVA9519ZXT
Siemens Transmitter 7MF4033-3GB10-1DB6
TRIAD Transformer F48-400-C2
IFM Sensor OU5030
Danfoss Solenoid Coil BG110DS
KITZ Check Valve UO-DN20
REXMAC Electric Motor RA63A4
YUKEN Vane Pump PV2R3-60-F-RAA-41
LEEMIN Filter TZX2-400-5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COSEL Power Supply MGW152412
SCHLEICHER Relay SNO4003K
XUANYI Vacuum Pump 2BV-2061
Recent related posts
-
03/10/2021
The main circuit fuse fusing is a common fault of SCR servo driver. The causes of fuse fusing are as follows
The "phase sequence" of power incoming line is incorrect. Due to the synchronization problem between the trigger pulse and the main circuit of SCR servo driver, there are strict requirements on the "phase sequence" of the input power supply. If the "phase sequence" is not correct, connecting the power supply may immediately cause the fuse of the main circuit of the driver to blow.
-
08/18/2020
Air-cooled chiller inspection steps and solutions
Generally, after using the air-cooled chiller for a long period of time, some problems cannot be avoided. If there is a failure, we should carefully check the operating conditions of the various parts of the machine.
-
11/12/2021
Basics of Industrial Control System and the Use of PLC
The components of industrial control system (ICS) can be roughly divided into two categories according to their location: control center equipment and remote site equipment.
-
07/20/2020
Six aspects of repair and maintenance of refrigeration compressors in cold storage
A. During the initial operation of the cold storage unit, carefully observe the oil return of the compressor and keep it clean. If you find that the oil level is not clean enough or if the oil level drops, you should add oil or replace it with new oil in time. This can avoid poor lubrication
-
08/16/2020
What is the emergency treatment method for R22 refrigerant leakage
R22 refrigerant has low toxicity, but some of the cracked gas and residual liquid components produced by using it to prepare tetrafluoroethylene are highly toxic, which can cause acute poisoning.
-
07/11/2023
Types of Compressors Used in HVAC Installation (with Pictures)
Heating, Ventilation, and Air Conditioning (HVAC) systems are essential components of modern buildings, providing thermal comfort and acceptable indoor air quality.
-
08/08/2022
Squirrel Cage Induction Motor Vs Wound Rotor Induction Motor: Rotor Structure, Pros and Cons
The three-phase induction motor consists of two basic parts: the stator and the rotor.
-
11/14/2023
Which Way Do Computer Fans Blow: 3 Seconds to Distinguish the Air Inlet and Outlet
The chassis fan is one of the very important accessories in the computer. It can effectively cool down the temperature, help the computer to dissipate heat and improve the stability of the entire system.
-
08/03/2020
What are the thermal state parameters of the refrigerant
The working fluid is constantly changing its thermal state. The physical quantity describing the thermal state of the working fluid is called the thermal state parameter of the working fluid, referred to as the state parameter.
-
07/24/2020
Classification, principle and use of refrigeration compressors
Classification, principle and use of refrigeration compressors<br></br> The function of refrigeration compressor:<br></br> The refrigeration compressor is the "heart" of the refrigeration system. It absorbs the refrigerant vapor from the evaporator, increases the pressure and discharges it to the condenser, so that the refrigerant circulates in the system. Can be used in refrigeration systems and heat pump systems