Air-cooled chiller inspection steps and solutions
Generally, after using the air-cooled chiller for a long period of time, some problems cannot be avoided. If there is a failure, we should carefully check the operating conditions of the various parts of the machine. Check the refrigeration system, electrical system, air system, and water system. To determine whether their work is normal, the editor below will analyze the inspection methods in detail with you.
First, refrigeration system
Check whether there are cracks, damages, frosting and condensation in each pipeline of the refrigeration system; whether there is friction between the refrigeration pipelines of the air-cooled chiller, and the pipeline and the shell, especially the welding of the refrigerant pipeline Whether there is leakage at the joints and joints, where there will be oil stains, clean soft cloth and soft paper can also be used to scrub the joints and the joints.
Second, electrical system
Check whether the fuse of the electrical system is blown, whether the insulation of the electrical wire is intact, whether the circuit board is cracked, whether the connection is loose, etc. In particular, whether the electrical connection is well-touched, and the wiring screws and connectors are easily loosened to cause poor touch.
Third, ventilation system
Check whether the air filter, heat exchanger coils and fins are too dusty; whether the air inlet and outlet are dredged; whether the fan and fan blades work normally; whether the wind force is normal, whether the water system is normal, etc. .
Four, machine water system
Check whether the water system is leaking; whether the water inlet and outlet are dredged; whether the water pump works normally. Listen to the power on and listen to the air-cooled chiller compressor working sound is normal, whether there is abnormal sound, whether there is noise in the operation of electric fans, water pump, whether the noise is too loud, etc. When the air-cooled chiller is working, the vibration is slight and the noise is small under normal conditions.
Touch the relevant parts of the air conditioner with your hands to feel the conditions such as cold and heat, tremor, etc., which helps to distinguish the nature and location of the problem. Under normal conditions, the temperature of the condenser gradually decreases from top to bottom, and the temperature of the lower part is slightly higher than the ambient temperature. If all the condensers are not hot or the upper part is slightly warm, or although the temperature is hot but there is a significant difference in the temperature of the two adjacent pipes, it is abnormal. The evaporator will feel cold and sticky if you put a finger dipped in water on the surface of the evaporator under normal conditions. The capillary tube at the dryer and the outlet should have a warm feeling under normal conditions, such as feeling lower than the ambient temperature or dew condensation on the surface and temperature difference in each section of the capillary are abnormal. The temperature of the suction pipe 20 cm away from the compressor should be similar to the ambient temperature under normal conditions.
In order to accurately determine the nature and location of the problem, it is often necessary to use instruments and appearance to check and measure the performance parameters and conditions of the air-cooled chiller. For example, use a leak detector to check for refrigerant leakage; use a multimeter to measure whether the power supply voltage, the ground current of each terminal and the working current meet the requirements, and the air conditioner controlled by the computer should also measure whether the potential of each control point is normal Wait.
Air-cooled chiller inspection steps and solutions
Recent related posts
-
08/18/2020
Air-cooled chiller inspection steps and solutions
Generally, after using the air-cooled chiller for a long period of time, some problems cannot be avoided. If there is a failure, we should carefully check the operating conditions of the various parts of the machine.
-
08/17/2020
Why is the meter still running after the air conditioner is shut down
In the process of using home appliances, friends will always encounter some weird problems more or less. For example, the air conditioner makes strange noises, the soymilk machine suddenly stops turning, and so on
-
08/17/2020
Why does industrial chiller have serious odor during use
After long-term operation of industrial chillers, if cleaning and maintenance are not carried out for a long time, the operational stability of industrial chillers will be greatly affected, and peculiar smells will appear.
-
08/17/2020
Why can't the cold storage temperature drop The evaporator is very important!
There are many reasons why the temperature of the cold storage cannot drop. The editor of okmarts.com lists the following six common phenomena for your reference:
-
08/17/2020
Who costs electricity for air-conditioning heating and cooling
Many friends who use air-conditioning know that air-conditioning heating costs more electricity than cooling, but many people do not know why air-conditioning heating costs more electricity than cooling? Why is there such a big difference in the use of th7ﰨ2 䀀 湠眷
-
08/17/2020
What should I do if there is insufficient refrigerant in the chiller
What should I do if there is insufficient refrigerant in the chiller? Today, the editor of okmarts.com will teach you the correct way to deal with it. Please remember it!
-
08/17/2020
What should I do if the compressor current of an industrial chiller is overloaded? okmarts.com editor has a coup!
The compressor current overload phenomenon of industrial chillers, cause analysis and solutions. The "overcurrent" here refers to the current overload of the chiller compressor.
-
08/17/2020
What problems with industrial chillers will alarm
In the process of using industrial chillers, many problems will cause industrial chillers to alarm. There are also many ways to alarm, usually light alarm, sound alarm and code alarm.
-
08/17/2020
What is the reason for the excessive leakage of the refrigeration compressor
1. Insufficient oil flow, increase the oil supply appropriately; 2, the assembly sequence of the refrigeration compressor stuffing box is unreasonable and should be assembled according to the procedure;
-
08/17/2020
What is the principle of the chiller shell and tube evaporator
The cold water shell and tube evaporator is made by expanding two-layer metal plates with high-pressure gas or by mechanical pressing. It can also be made of aluminum alloy die-casting.