YIDA Magnet Pump CQF20-20-110
- Specifications
- Q&A
- Reviews
Maximum flow rate: 120 L/min
Maximum pumping head: 14.5 m
Standard flow rate: 92 L/min
Standard pumping head: 10 m
In/Out diameter: 20/20 mm
Voltage: 220/380V
Motor power: 0.37 kW
PAN WORLD Magnet Pump NH-400PS-CV
Becker Vacuum Pump DT4.16K
Iwaki Diaphragm Pump LK-F55VS-04
PROCON Water Pump 104R265R12BA170
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COKERY Belt V15X840
Nidec Fan A30318-10
CHINT Contactor CJX1-170/22
09/07/2020
The main circuit is the power conversion part that provides the voltage and frequency power supply for the asynchronous motor. The main circuit of the frequency converter can be roughly divided into two categories:
09/08/2020
The difference between air-cooled screw machine and water-cooled screw machine: The oil cooler of the air-cooled screw compressor and the compressed air after-cooler are made into one body. It is an aluminum plate-fin structure and brazed in a vacuum furnace. Once the oil leaks, it is almost irreparable and only replaced. The working principle is that hot oil and high temperature (about 80℃) gas flow in their respective pipes,
01/23/2023
When faults occur, there will be various alarm codes on the Spindle amplifier, each representing different faults.
07/05/2020
Notes on long-term shutdown of Hitachi air compressors during long holidays Thank you very much for your strong support for Hitachi Air Compressor sales and after-sales service!
06/14/2020
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!
08/15/2020
Enterprise users who use refrigerators are more concerned about the cost of use. The editor of okmarts.com believes that only by saving energy can the cost of enterprise use be effectively saved.
09/02/2020
1 Installation environment layout requirements In order to meet the needs of development, the computer room should have room for expansion in the position of the general map.
08/07/2020
1. Chilled water pump:<br></br> In the chilled water loop, a device that drives water to circulate. The end of the air-conditioned room (such as fan coil, air handling unit, etc.)
11/05/2022
The thermostatic expansion valve (TXV or TEV), also called the thermal expansion valve, controls the openness degree through the control of the superheat of the gaseous refrigerant at the outlet of the evaporator.
08/01/2022
Remove the cover, screw in the central screw hole with clean screws, and lift out the crankshaft