There is no price at present, you can Request a Quote
Series | PV2R24A Series |
Brand | Yuken |
Pump Type | Double Vane Pump |
Small Volume Pump Nominal Displacement cm³/rev | 41 |
Large Volume Pump Nominal Displacement cm³/rev | 193 |
Mounitng | Foot Mtg. |
Direction of Rotation | Clockwise |
Small Volume Pump Discharge Port Position | Upwards |
Large Volume Pump Discharge Port Position | Upwards |
Mass (Approx.) | 70 kg |
YUKEN Vane Pump F-PV2R24A-41-193-L-RAAA-10
There is no price at present, you can Request a Quote
People who bought this item also viewed
Eaton Vickers Vane Pump V20-1S7S-1C11
YUKEN Vane Pump PV2R1-25-L-RAA-40
YUKEN Vane Pump PV2R1-23-F-RAA-41
YUKEN Vane Pump PV2R1-14-F-RAA-4190
YUKEN Vane Pump AR22-FR01C-20
TOKYO KEIKI Vane Pump SQP2-21-86-C-18
HONGYI Vane Pump 20V10A-1C22R
Parker Denison Vane Pump PV2R1-10-F-RAA-4222
Kompass Vane Pump VFD1-30F-A4
SMC Proportional Valve ITV3010-04N2BN4
NACHI Check Valve OCH-G04-A3-10
JIE&MING Overflow Valve Y2-HD20L
NACHI Piston Pump PVS-1B-22C3A4-U-12
Shimadzu Gear Pump SGP1A32F2H2-R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Schneider Contactor LC1D25F7C
PANASONIC Capacitor 80V 1200UF
Baumer Sensor UNAM 12N3914/S14
NKK Switch SK15BG30
Renishaw Encoder RGH22C05F00A
Recent related posts
-
09/06/2020
Discussion on air filtration detection technology
With the increase of smog in the north, filtration and purification industries such as air purification and fresh air have ushered in a new spring, which also detonated the entire filter industry.
-
06/29/2020
The role of freezing oil in screw refrigeration compressor
The role of freezing oil in screw refrigeration compressor The role of lubricating oil: 1) A dynamic seal is formed between the screw and the compression chamber and the male and female screws to reduce refrigerant leakage from the high-pressure side to the low-pressure side during the compression process.
-
07/31/2020
The 8 accessory usages that must be mastered when using computer room air conditioners!
The electrical control and air circulation of the computer room air conditioner are independent units. During maintenance and overhaul, the air conditioner does not need to be turned off, and the stable air flow and temperature gradient in the air conditioner room can also be ensured
-
07/03/2020
Global HVAC Centrifugal Compressors Market 2020-2025 Report and Imapct of Coronavirus Pandemic
The “Portable Air Compressor” Market report considers the central point responsible for driving the development of the Snowblowers Industry, notwithstanding the key preventions and difficulties.
-
08/16/2020
The difference between condenser and cooler
There will be compressors, condensers, evaporators, expansion valves and refrigerants in the chiller refrigeration system. Only with the addition of these original parts will a good refrigeration system be formed.
-
09/09/2020
Basic knowledge of gas compressor and its role in various fields
1.Compressor power and pressure: 1. The shaft power of the compressor is the sum of the indicated power and the friction power. The indicated power is the power directly consumed by compressed gas, the friction power is the power consumed by overcoming mechanical friction, and the shaft power of the compressor is the power used to select the drive motor.
-
01/07/2021
The method to identify the failure of the totally enclosed refrigeration compressor is very effective!
The method to identify the failure of the totally enclosed refrigeration compressor is very effective! 1. How to identify the three binding posts on the casing of the hermetic compressor? Running end (R), starting end (S), common end (C), the re 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱
-
08/23/2020
Teach you ten major inspection standards to see the pros and cons of air conditioners
The hot summer is approaching the peak season for air-conditioning sales and the peak period for consumers to purchase air-conditioners. Many small partners are often at a loss when faced with the variety of products on the market.
-
09/01/2022
Differences between a Contactor and a Relay
The contactor and the relay are all control devices used in electric circuit. But they cannot replace each other. The followings are the main differences between the two.
-
08/03/2022
FANUC Spindle Amplifier Alarm Codes and Solutions (1)
FANUC CNC system has two mainstream servo drive amplifiers - αi and βi series servo drive amplifiers.