Ziehl Abegg Fan RH40M.4DK.4C.1R
People who bought this item also viewed
KAKU Fan KA2206HA2-2
EVERFLOW Fan T127010BU
Ebmpapst Fan A2E210-AF02-09
Ziehl Abegg Fan FN050-VDK.4I.A7P1
Ziehl Abegg Fan RH25V-6IK.BA.1R
Ziehl Abegg Fan FN100-SDQ.7Q.V5P1
Ziehl Abegg Fan FN030-4EK.WC.V7
Y.S.TECH Fan FD248025HS
Sanyo Denki Fan 9BMB24P2K22
Sanyo Denki Fan 109P0412H9D11
SUNON Fan PMD2406PTB1-A
LG Compressor QP442PBA
OMRON Power Supply S8VM-15224C
TRIAD Transformer TCT40-08E07AB
Siemens Circuit Breaker 5SU9346-1CR10
Eaton Contactor DILEM4(240V50HZ)
BROAD-OCEAN Electric Motor FN35B-ZL
Donaldson Filter P181137
KEYENCE Input Output ModuleKL-8BXT
PHOENIX Relay 2981017
Nichicon Capacitor VX 16V 47UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Honeywell Switch HCS-80-A220
COKERY Belt 3-7M730-JB
Honeywell Actuator ML7421B1023-E
Recent related posts
-
07/18/2020
The role of precision chillers in various industries
Piston refrigeration compressor liquid hammer process and reasons for liquid hammer 1. Introduction The phenomenon that liquid refrigerant and/or lubricating oil is sucked into the compressor cylinder with the gas and damaged the suction valve plate
-
06/23/2020
Advantages and disadvantages of Hitachi central air conditioning
At present, the central air-conditioning of the refrigerant system is still the best done by Japanese brands. When it comes to Japanese central air-conditioning, one has to say that Hitachi, one of the Japanese air-conditioning BOSS, is a well-known international central air-conditioning brand. Most air conditioners now use scroll compressors as the core of power, and the world’s first scroll machine for air conditioning was manufactured by Hitachi in 1983.
-
06/21/2020
Working principle of sliding vane compressor_Features of sliding vane compressor
Working principle of sliding vane compressor <img src="{{media url="magefan_blog/Working_principle_of_scroll_compressor_Characteristics_of_scroll_compressor.jpg"}}" alt="" /> Air is sucked in through a filter and a regulating proportional valve. The regulating valve is mainly used to regulate the pressure chamber formed by the rotor and slide of the air cylinder. The rotor rotates eccentrically with respect to the cylinder, the valve plate is installed in the rotor groove, and the slider is pushed to the cylinder wall by centrifugal force.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/07/2020
The essentials of air compressor selection
When buying an air compressor, in addition to the purchase cost, how to reduce electricity expenses? How to extend the service life of the air compressor? How to provide air pressure smoothly?
-
08/09/2020
What is the reason that the temperature of the freezer cannot drop
It is a common phenomenon that the temperature of the supermarket freezer does not drop and the temperature drops slowly. Now I will briefly analyze the reasons for the slow temperature drop, hoping to bring some help to friends in the industry.
-
09/11/2020
Discussion on the Key Technology of DC Inverter Air Conditioner Control
Inverter air conditioners have become a hot spot for the development of air-conditioning companies because of their energy-saving, comfortable, and high-energy-efficiency advantages and conform to the national policy of "energy saving and emission reduction".
-
01/09/2024
Cooling Tower Troubleshooting and Solutions
Cooling towers are commonly used equipment in industry, air conditioning and other fields, and are used to remove the large amounts of heat generated during the production process.
-
07/02/2020
Compressor operation in the heart of the refrigeration system in 2020
Compressor operation in the heart of the refrigeration system in 2020 A compressor is a fluid machine that raises low-pressure gas to high-pressure gas. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and discharges high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle, thereby achieving compression-condensation (heat release) )-Expansion-evaporation (heat absorption) refrigeration cycle.
-
09/04/2020
Factors affecting the use of oil-free air compressors
The oil-free air compressor is the main body of the air source device. It is a device that converts the mechanical energy of the prime mover into gas pressure energy and is a pressure generating device for compressed air. The factors that affect its use are: