How to avoid water leakage in central air conditioner

The core problem of compressor oper

How to avoid water leakage in central air conditioner

In the hot summer, there is nothing more comfortable than staying in an air-conditioned room. If there is, it must be blowing on the air conditioner, eating iced watermelon, playing with the mobile phone... If you encounter the problem of water leakage in the central air conditioner at this time, it is true. So disappointing. With the improvement of living standards, household central air conditioners have become popular due to their advantages of comfort, intelligence, and environmental protection, and can be coordinated with the overall decoration style through clever design and installation, so that the indoor unit is hidden in the ceiling without affecting The interior decoration style can meet the individual needs of different people. What caused the central air conditioner to leak? Let's take a look at the following together!

  ①, the air humidity is high

Summer air humidity is high. When using central air conditioner, if the humidity at the air outlet of the air conditioner is particularly high, and the indoor humidity is high, the water vapor generated during the operation of the air conditioner is easy to condense into water droplets. The more water droplets accumulate, the water leakage phenomenon will appear. !

  ②, installation problem

   three points of equipment, seven points of installation. If the position of the indoor unit of the air conditioner is shifted, the drain pipe will not drain smoothly or the levelness will be unqualified, and the water will leak due to excessive water accumulation. Another point is that the hole in the wall is too high during installation, which leads to a higher position on the side of the drain pipe, which will cause the drain pipe to not drain smoothly. If the indoor unit is improperly installed and the connection between the drain pipe and the indoor unit is not tight, condensed water will flow out of the gap, causing water leakage. These problems will cause water leakage in the central air conditioner.

  ③、Pipe insulation

At present, the indoor piping of household central air-conditioning is basically made of copper pipes. Because the temperature of the refrigerant circulating in the copper pipes is very low, if the quality of the insulation cotton is poor or the insulation cotton is not tightly wrapped, it will not have a good insulation effect. Condensation will be caused on the surface, and the water will drip down after it accumulates less and more, soaking the ceiling or even the wall, causing the wall paint to fall off.

  ④, improper use of air conditioner

   When the water that is not easily discharged from the drain pipe gradually overflows to the water receiving slot in the room, water leakage will occur.

  Solution small coup:

   Water leakage from the air outlet of the central air conditioner does not mean that there is a problem with the central air conditioner. Check whether the doors and windows are closed properly, slightly increase the supply air temperature, and adjust the airflow angle. If the problem persists, you can ask a professional central air conditioner debugger to deal with it on site. The air outlets of central air conditioners are mainly made of wood materials, aluminum alloy materials and ABS materials. Due to the high cost performance and moderate price, many families use aluminum alloy air outlets, but it should be noted that when cooling in summer, The supply air temperature is too low, the heat preservation is not done well during construction, and the aluminum alloy material air outlet is prone to condensation;

When the central air conditioner is installed and constructed, make sure that the condensate drain gradient cannot be lower than 1/100. Before connecting the drain pipe to the indoor unit, check whether the indoor unit drain port is dirty or blocked. After installation, in order to avoid water leakage If it happens, after connecting the indoor unit and the drain pipe, a drain test should be carried out to ensure that no water leaks.

For thermal insulation, try to choose high-density, flame-retardant thermal insulation. Copper pipes of different pipe diameters should use thermal insulation cotton with corresponding aperture. When wrapping thermal insulation cotton, be careful not to leave any gap between the thermal insulation cotton and the copper pipe, and ensure that the copper The tube will not be exposed at all, and prevent the air conditioner from leaking at the source.

When turning on the air conditioner, do not turn it on to the low temperature of z* at one time. At first, the temperature can be turned on to 28-29 degrees Celsius. After you adapt, adjust the temperature. It is not that the lower the temperature, the better. This will affect the machine itself. Affect the cooling effect of the machine later.