Fluid: Air(to be filtered by 40u m filter element)
Mounting type: Basic FA LB TC TCM1
Operating pressure: 0.15 to 1.0 Mpa(22 to 145psi)(1.5 to 10.0bar)
Proof pressure: 1.5MPa(215psi)(15bar)
Temperature(degrees Celsius): -20 to 70
Speed range(mm per second): 30 to 800
Cushion type: Variable cushion
Bore size: 32mm
Stroke1: 700mm
Stroke2: 700mm
AirTAC AirPneumatic Cylinder SCT32X700X700 StandardPneumatic Cylinder(Double acting muti-position type)
People who bought this item also viewed
Festo Air Cylinder DGP-32-600-PPV-A-B-KH-GK
AirTAC Air Cylinder BSC32X75S
AirTAC Air Cylinder ACE32X125
AirTAC Air Cylinder TCL12X30S
AirTAC Air Cylinder SCD125X150
MINDMAN Air Cylinder MCQA-11-80-50
Festo Air Cylinder ADVULQ-25-30-A-P-A
CKD Air Cylinder STK-20-20-N11
Festo Air Cylinder DSBC-125-500-C-PPVA
SIEMENS Actuator SAX61.03
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Belimo Actuator GR230A-7
AirTAC Air Cylinder SDAT63X100X100
Contrinex Sensor ND8-S4S1-M12
IFM Sensor IM513Q
UNIVER Solenoid Valve BE-6940
Recent related posts
-
09/26/2023
Types of Water Chillers (Chiller Basics, Condenser Type and Compressor Type)
Water chillers are machines that are used to cool water and maintain a specific temperature for various industrial processes.
-
08/19/2020
Which air conditioner, floor heating, or radiator consumes the most electricity
At present, the household heating methods of the residents in the north and south of our country are becoming more and more diversified. Radiators, air conditioners, and floor heating are the three most common household heating methods.
-
06/14/2020
Analysis of the causes of liquid compressor blowdown
The phenomenon that the liquid refrigerant and/or lubricating oil of the refrigeration system damages the suction valve piece when the gas is sucked into the compressor cylinder, and is not quickly discharged during the exhaust process after entering the 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧؎ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
01/07/2023
What is a Color Coded Inductor Coil?
Similar to color-ring resistors, color coded inductor solenoid coils use colors to represent different numbers, which can indicate the inductance of the inductor.
-
08/16/2020
How to install a water-cooled screw chiller
Before using the water-cooled screw chiller, you need to know the installation requirements of the chiller, so that it will reduce a lot of unnecessary troubles during operation.
-
07/05/2020
Full analysis of high-temperature burn-down failure of scroll compressor
Full analysis of high-temperature burn-down failure of scroll compressor Scroll compressor overheating at high temperature for a long time will not only reduce the insulation performance and reliability of the motor, shorten the life of the motor, but also reduce the lubricating ability of the lubricating oil, and even cause carbonization and acid hydrolysis of the lubricating oil.
-
06/14/2020
How important is the installation environment of the refrigeration unit It is enough to do these 4 points!
How important is the installation environment of the refrigeration unit It is enough to do these 4 points! The refrigeration equipment (compressor unit) is installed in the machine room, and the surrounding environment should be maintained:
-
08/04/2020
The advantages and disadvantages of the fluorine system and the water system are compared!
The advantages and disadvantages of the fluorine system and the water system are compared! Central air-conditioning is mainly divided into two categories: fluorine system and water system, both of which are connected to multiple indoor units by one outdoor unit,
-
09/09/2020
Classification of air filters
Air filter has three methods: inertia, filtration and oil bath. ①Inertial type: Since the density of impurities is higher than that of air, when the impurities rotate or make sharp turns with the air, the centrifugal inertial force can separate the impurities from the airflow.
-
07/27/2020
The advantages and disadvantages of 5 central air-conditioning compressors are big PK
Do you know the advantages and disadvantages of piston compressors, rolling rotor compressors, scroll compressors, screw compressors, and centrifugal compressors? This article explains these 5 compressors in detail.