Fluid: Air(to be filtered by 40u m filter element)
Operating pressure:
Double acting: 0.1 to 1.0 Mpa(15 to 145psi)(1.0 to 10.0 bar)
Single acting: 0.2 to 1.0 Mpa(28 to 145psi)(2.0 to 10.0 bar)
Proof pressure: 1.5MPa(215psi)(15bar)
Temperature(degrees Celsius): -20 to 80
Speed range(mm per second):
Double acting: 30 to 500
Single acting: 50 to 500
Magnet: Without magnet
Bore size: 12mm
Stroke: 20mm
Adjustable stroke: 10mm
AirTAC Air Cylinder Pneumatic ACQJ12X20-10 Model:Compact Cylinder Pneumatic(Adjustable stroke)
People who bought this item also viewed
CKD Air Cylinder STSB-4010
AirTAC Air Cylinder HRQ10
AirTAC Air Cylinder SC32X25S
AirTAC Air Cylinder ACQ80X40
AirTAC Air Cylinder SC40X25
MINDMAN Air Cylinder MCSS-6-30-AS
MINDMAN Air Cylinder MCJQ2-11-16-30M
SHAKO Air Cylinder PC25B25-C
ELCO Encoder EB58M15Q-P4JR-1024
PNEUMAX Solenoid Valve 228.32.4.13
Belimo Actuator NF24-S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Dwyer Transmitter ISDP-016
SMC Solenoid Valve SY5320-5DD-01
Honeywell Sensor 79380-00
Recent related posts
-
11/06/2022
What is an Electronic Expansion Valve?
The electronic expansion valve is a kind of the expansion valve. It uses the electrical signal generated by the adjusted parameters to control the voltage or current applied to the expansion valve, thereby achieving the purpose of adjusting the liquid supply.
-
07/05/2020
Hitachi 6HP Inverter Compressor-Compressor
Hitachi 6HP Inverter Compressor-Compressor Why is frost formed between the electronic expansion valve and the compressor? A customer asked: The compressor is suddenly not cooling, and the electronic expansion valve is frosted to the compressor. Is there any relationship between the two before?
-
08/08/2020
Reasons for condensation at the bottom of the condenser
Reasons for condensation at the bottom of the condenser 1. It is abnormal if condensation occurs at the bottom of the condenser when the unit is running. It may be the reason for the low amount of refrigerant.
-
06/13/2020
The difference between single and twin screw compressors is reflected in the following 6 aspects
The difference between single and twin screw compressors is reflected in the following 6 aspects
-
08/05/2020
How does the air conditioner collect fluoride
1. Method: The method of collecting fluorine should be correct. Under the state of turning on and cooling, open the covers of the two connecting pipe valves of the outdoor unit with a wrench, use 5 hexagonal wrenches,
-
06/29/2020
Causes of non-condensable gas in refrigeration system
Causes of non-condensable gas in refrigeration system 1. Insufficient emptying of the refrigeration system before charging the refrigerant Before charging the refrigerator, the compressor cylinder in the refrigeration system, the condenser, the evaporator, and the piping of the system were filled with air. In order to eliminate these air before charging the refrigerant, the interior of the refrigeration system Vacuuming,
-
07/12/2020
Future trends of semi-hermetic screw compressors? Unseen companies may be eliminated2
Future trends of semi-hermetic screw compressors? Unseen companies may be eliminated From single-screw to single-machine two-stage, from ordinary type to frequency conversion, environmental protection, energy-saving type, from a single product to the provision of system solutions, the development of semi-hermetic screw compressors has never stopped and has continuously penetrated into major refrigeration projects.
-
05/03/2022
How to Deal With 6 Common Faults of Contactor?
Cause: The short-circuit ring of AC contactor is broken or the end faces of dynamic iron cores and static iron cores are uneven; Skewed or dirty.
-
06/13/2023
Refrigerator Compressor Not Running and What to Do?
When it comes to refrigeration, the compressor is one of the most crucial components. It plays a vital role in keeping your refrigerator running, as it's responsible for pumping refrigerant throughout the system.
-
06/22/2020
Which refrigerator is better for cooling
Different cooling methods of refrigerators have different advantages, mainly depending on which cooling method is selected. The direct cooling refrigeration type is cheap, relatively energy-saving, and has good fresh-keeping and moisturizing properties, but the temperature is uneven, and it needs to be defrosted frequently.