Fluid: Air(to be filtered by 40u m filter element)
Operating pressure:
Double acting: 0.1 to 1.0 Mpa(15 to 145psi)(1.0 to 10.0 bar)
Single acting: 0.2 to 1.0 Mpa(28 to 145psi)(2.0 to 10.0 bar)
Proof pressure: 1.5MPa(215psi)(15bar)
Temperature(degrees Celsius): -20 to 70
Speed range(mm per second):
Double acting: 30 to 800
Single acting: 50 to 800
Cushion type: Bumper
Magnet: without magnet
Bore size: 16mm
Stroke: 400mm
Adjustable stroke: 100mm
AirTAC Air Cylinder Pneumatic MIJ16X400-100Mini Cylinder Pneumatic(Adjustable stroke)
People who bought this item also viewed
CKD Air Cylinder SCPG2-M-00-10-30
CKD Air Cylinder STSB-4010
AirTAC Air Cylinder SC160X150
AirTAC Air Cylinder SC125X110S
MINDMAN Air Cylinder MCJS-11-25-25
CKD Air Cylinder SSD2-KL-32-40-W1
Festo Air Cylinder DSN-16-160-PPV
SunYeh Actuator OM-A-M
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron Light Curtain F3SJ-A0950P20-01TS
COMAIR ROTRON Fan JQ12B6TDNX
Siemens Contactor 3RT1075-6AV36
DENISON Piston Pump PD045PS02SRS5AC10R100000
Recent related posts
-
12/13/2023
R410a VS R134a: Comparison of Commonly Used Refrigerants in Data Centers
At present, data centers mainly use two types of refrigerants. One is R410a, which is mainly used in small or medium-sized data centers with air conditioning cooling capacity of 300-400 KW.
-
06/09/2022
Use of Safety Light Curtain
The electric sensitive protection equipment can play the role of protection tripping or induction, and its composition at least includes
-
09/16/2020
SKF bearing life theory and formula
For modern high-quality bearings, the nominal or basic rating life may be very different from the actual life in a particular application. In a particular application, the service life is affected by various factors, including lubrication, pollution degree, misalignment degree, correct installation and environmental factors.
-
03/13/2021
Working mode of servo driver
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)
-
04/27/2023
Mitsubishi vs. Daikin vs. Hitachi vs. Toshiba: Which is the Best Central Air Conditioner Brand?
Decoration is an extremely exhausting task. From planning to completion of the decoration, the trouble and trivialities of the whole process make people not want to go through it again, and even just a certain procedure in the decoration process will make people scream and have a headache.
-
09/07/2020
An article to fully understand the principle, failure and maintenance of nitrogen compressors
Nitrogen compressors are mainly used in various industrial needs. Pipes are used to connect the original air inlet of the nitrogen compressors and the balance gas tank. When the sealing performance of the sealing box is not very good, the pipeline provides a certain pressure ,
-
09/05/2020
Analysis on the components of compressed air system
The compressed air system is composed of the air supply end to the air consumption end as follows: air compressor→air storage tank→filter→dryer→air pipeline→air port.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/06/2020
The working principle of the frequency converter
The main circuit is the power conversion part that provides the voltage and frequency power supply for the asynchronous motor. The main circuit of the frequency converter can be roughly divided into two categories:
-
08/05/2020
Selection skills of precision air conditioner and comfort air conditioner
When doing intelligent and informatized projects, it is inevitable to do computer room projects. Air-conditioning is inevitable for computer room engineering. Some people will say that the cost of precision air-conditioning is so high.