Fluid: Air(to be filtered by 40u m filter element)
Operating pressure:
Double acting: 0.1 to 1.0 Mpa(15 to 145psi)(1.0 to 10.0 bar)
Single acting: 0.2 to 1.0 Mpa(28 to 145psi)(2.0 to 10.0 bar)
Proof pressure: 1.5MPa(215psi)(15bar)
Temperature(degrees Celsius): -20 to 70
Speed range(mm per second):
Double acting: 30 to 800
Single acting: 50 to 800
Cushion type: Bumper
Magnet: without magnet
Bore size: 25mm
Stroke: 125mm
Adjustable stroke: 10mm
AirTAC Air Cylinder Pneumatic MIJ25X125-10Mini Cylinder Pneumatic(Adjustable stroke)
People who bought this item also viewed
CHANTO Air Cylinder JUR25X15
Festo Air Cylinder DGP-32-600-PPV-A-B
MINDMAN Air Cylinder MCMJ-11-10-10-B
AirTAC Air Cylinder MA25X80-S-U
AirTAC Air Cylinder HLH16X50S
Festo Air Cylinder ADN-63-50-A-P-A
KOGANEI Air Cylinder DA20X60-12
CKD Air Cylinder STSB-2510
MINDMAN Air Cylinder MCMB-11-32-75
Autonics Rotary Encoder ENA-2-3-N-5
SIEMENS Actuator GLB336.2E
SMC Proportional Valve ITV2030-042CS
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Motorola Integrated Circuit MC10231P
Dwyer Switch PR-153-P1 PG
Bristol Compressor H82J183DBL
Recent related posts
-
04/16/2024
Why Do Servo Motors Fail? 9 Parts that May Malfunction with Pictures
Keeping servo motors running in optimal condition is crucial for any industrial business, especially for industries such as robotics or CNC machine tools, as the cost of downtime caused by servo motor failure can be very expensive, both financially and in terms of time.
-
06/13/2020
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal, whether the fuse has been blown due to starting overload
-
09/04/2020
Have you considered these four questions when using screw air compressors
When using a screw air compressor, have you considered these four issues: the speed of the screw air compressor, the working temperature of the screw air compressor, the lubrication method of the screw air compressor, and the use environment of the screw air compressor.
-
07/27/2020
What is the refrigeration pressure of the inverter air conditioner? What is the refrigerant of inverter air conditioner?
It is necessary to find a good air conditioner to be able to reassure people. Inverter air conditioners are really good and are loved by people. So when people use such air conditioners, they should also know the refrigeration pressure of inverter air conditioners. At the same time, we should know what the refrigerant of inverter air conditioner is, so that it can be more helpful to the use of air conditioner.
-
08/13/2020
Water-cooled chillers need to be cautious when choosing cooling towers
In many special use environments, companies need to apply water-cooled chillers. Because water-cooled chillers need the help of cooling towers during operation, they need to follow the
-
08/15/2020
Simple treatment method after the refrigeration system enters water
Since the chiller has a water system, there is a possibility that the refrigerant system may enter water when it is used improperly. Therefore, a process guide is formulated for the problem of water ingress
-
07/18/2020
reasons why the constant temperature and humidity test chamber does not cool
1. Introduction The phenomenon that liquid refrigerant and/or lubricating oil damage the suction valve plate when the gas is sucked into the cylinder of the compressor, and it is produced when the piston is compressed when the piston is close to the top dead center and is not quickly discharged during the exhaust process after entering the cylinder.
-
06/29/2020
What are the causes treatment and prevention methods of compressor liquid blow
What are the causes, treatment and prevention methods of compressor liquid blow Liquid blow means that the refrigerant liquid or wet steam is sucked into the compressor by the compressor due to failure or insufficient absorption of heat, which is called liquid blow. First, the main reasons are as follows:
-
09/04/2020
Graphic-the structure of air compressor
An air compressor is an air compressor. It is a device that provides compressed air to various workshops in the factory. It compresses the atmospheric air sucked in from the outside through mechanisms such as screws and bolts
-
01/15/2021
Dafoss high-pressure
High pressure Compressor Compressor discharge pipe too hot Probable bellows leak in KVC capacity regulator. Solution Slowly loosen protective cap. If pressure or traces of refrigerant exist under the cap,there is a leak in the bellows.Replace val