Fluid: Air(to be filtered by 40u m filter element)
Operating pressure:
Double acting: 0.2 to 0.7 Mpa(28 to 100psi)(2.0 to 7.0 bar) or 0.1 to 0.7 Mpa(15 to 100psi) (1.0 to 7.0 bar)
Single acting: 0.3 to 0.7 Mpa(36 to 100psi)(3.0 to 7.0 bar)or 0.2 to 0.7 Mpa(28 to 100psi)(2.0 to 7.0 bar)
Proof pressure: 1.1MPa(160psi)
Temperature(degrees Celsius): -20 to 70
Speed range(mm per second): 30 to 500 or 50 to 800
Cushion type: No cushion or Bumper
Bore size:4mm
Stroke:125mm
Magnet:with magnet
AirTAC Air Cylinder Pneumatic PB4X125SPen size Cylinder Pneumatic(Double acting)
People who bought this item also viewed
Festo Air Cylinder SLG-18-200-YSR-A
Compact Air Cylinder QJ92-1642-A
CKD Air Cylinder SCPG2-M-00-10-30
AirTAC Air Cylinder ACQ50X40S
AirTAC Air Cylinder ACQ12X10
AirTAC Air Cylinder MA25X25SCA
Festo Air Cylinder ADNGF-32-60-P-A
Festo Air Cylinder DNC-63-160-PPV-A-KP
Festo Air Cylinder DNU-63-150-PPV-A
Festo Air Cylinder DMML-16-20-P-A
HENGSTLER Encoder RI58-O/6000EK.42KB
AirTac Solenoid Valve 4M210-08A
Belimo Actuator NRQU24-SR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MINDMAN Air Cylinder MCJS-11-80-75
PROFIT Planetary Reducer WPL120-3-S2-P2
Fuji Relay MA-415A
Contrinex Sensor PL-M18S-E0-010
Recent related posts
-
06/14/2020
Air-conditioning product structure changes, rotary compressor 1 HP 1.5 HP is still the dominant model
Statistics show that at present, in terms of product structure of rotary compressors, 1 horse and 1.5 horses are still the dominant models. During the cold year of 09-13, the two industries accounted for between 50-60% of the total; followed by 1 horse Th ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់變ᩄ
-
08/23/2020
What kind of equipment is suitable for high and low pressure refrigerant charging method
There are generally two types of refrigerant charging methods: low-pressure charging and high-pressure charging. The advantage of the low pressure charging method is that it is easier to control the amount of refrigerant charged,
-
06/14/2020
Cause Analysis of Refrigeration Compressor
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal,
-
09/07/2020
Year-end overhaul of compressor equipment in tire service industry
Partial maintenance of oil-water separator The main function of the oil-water separator is to adjust the system pressure and ensure system lubrication. Insufficient system pressure will cause the tire changer to work weakly, and lubrication failure will cause damage to the tire changer cylinder or wasted oil injection.
-
06/14/2020
Data Center Refrigeration System 41 Questions and Answers
How to repair the air conditioner compressor failure In summer, air conditioning is used more often, and the cooling effect of the air conditioner depends on the compressor, so once the cooling effect disappears, it means that the compressor has failed. 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
08/20/2020
Operation method for filling freon in refrigeration system of high and low temperature box
The operation method of filling Freon in the refrigeration system of the high and low temperature box is as follows: 1, prepare a scale, weigh the freon cylinder, and record the net weight of the total weight Leon.
-
08/11/2020
Installation of fittings of air-conditioning water system
Air-conditioning water system includes cooling water system (cooling water pipe, pump, cooling tower, condenser, valve, etc.), chilled water system (chilling water pipe, pump, terminal, valve, insulation, expansion tank, etc.) and condensate water system
-
09/02/2020
Calculation method of air compressor cooling tower selection
More and more air compressors use water cooling, but when it comes to calculating the size of the cooling tower, people often don't know where to start.
-
09/29/2022
What is Positive Displacement Pump?
<strong>Positive displacement pump</strong> is also known as a volumetric pump, which uses the periodic volume changes of the working chamber (pump casing or cylinder) in the pump to transport the liquid.
-
06/14/2020
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass"
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass" The energy regulation of the system is generally composed of the following ways: Compressor parallel-multi-stage contro 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ