Bore size:40
Temp.:-20...70 degrees Celsius
Speed range mm/s:30...800
Adjustable cushion stroke:21
AirTAC Air Cylinder SC40X295S
People who bought this item also viewed
Festo Air Cylinder DGC-25-625-KF-PPV-A
CAMOZZI Air Cylinder 61M2P063A0305
Festo Air Cylinder CRDNG-125-100-PPV-A
AirTAC Air Cylinder SC63X370S
AirTAC Air Cylinder SC50X60S
AirTAC Air Cylinder SC63X50
CKD Air Cylinder MDC2-X-4-3
Festo Air Cylinder DFM-50-50-P-A-GF
Festo Air Cylinder DNC-32-145-PPV-A
Festo Air Cylinder DGSL-20-10-P1A
HENGSTLER Encoder RI76TD/2500AD.4A42RF
Honeywell Actuator ML6425A3014
SMC Proportional Valve ITV2050-403BN
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KSK Oil SealTC(FKM)40X65X8
HENGSTLER Encoder RI76TD/8192ED.4N15RF
Littelfuse Fuse BLN003
Rosemount Transmitter 3051CD1A22A1AM5B4
Honeywell Sensor SDX05D4-A
Recent related posts
-
07/27/2020
Selection and comparison of compressors
1. Piston compressor (the work of the piston compressor is the continuous change of the working volume formed by the cylinder, the valve and the reciprocating piston in the cylinder).
-
09/18/2020
Performance comparison between piston compressor and screw compressor
The noise of the piston engine is loud and the maintenance is inconvenient. Most piston machines often have problems during use, which brings great inconvenience to users. At the same time, it can reduce the production cost of the factory, increase economic benefits, facilitate equipment management
-
06/13/2020
Commercial Refrigeration Compressor Market to Surge at 221.7 Million units by 2026; Introduction of Advanced Technologies to promote Growth, Says Fortune Business Insights™
Key Companies Covered in Commercial Refrigeration Compressor Market Research Report Are Carrier Corporation, Daikin Industries Ltd., Johnson Controls Pvt. Ltd., Mitsubishi Electric, Bitzer, Emerson Climate Technologies, Ingersoll Rand Inc., Rechi Precisio 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
07/17/2020
refrigerating system
4.1 Pressure vessels and pipelines are often contacted by refrigeration and air-conditioning technicians;; components of various systems; for example, placing an R--22 refrigerant storage tank on the rear panel of a car with a common barrier; The hot summer sun can make the temperature of the steel pipe reach 110F; the total area of
-
08/15/2020
How much is the temperature control of the industrial chiller How to set it up
Industrial chillers are commonly used refrigeration equipment in the industrial refrigeration industry, with a wide range of types, complete models, affordable prices, and can be customized for a wide range of applications.
-
07/23/2020
The damage of air-conditioning refrigeration compressor and its preventive measures
An 82000DWT bulk carrier of a shipping company broke down on the 7th day after leaving the factory. The crew described that when it started, the air-conditioning refrigeration compressor could not run continuously, and a large current occurred and an alarm was triggered.
-
07/02/2020
The compressor lacks oil, so the harm is so great!
The compressor lacks oil, so the harm is so great! Compressors are complex machines that operate at high speeds. Ensuring adequate lubrication of moving parts such as compressor crankshafts, bearings, connecting rods, and pistons is the basic requirement for maintaining normal operation of the machine.
-
05/26/2022
Level of Safety Light Curtain?
In modern chemical plants, people work together with mechanical equipment. Mechanical equipment is becoming more and more automatic, and workers are more and more likely to be hurt.
-
12/11/2022
How to Deal with the Abnormal Noises from the Linear Guideways?
The rolling element on the slider of the linear guideway moving back and forth inside the track groove will produce noise, which is a normal phenomenon.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.