There is no price at present, you can Request a Quote
double solenoid, 3 positions, spring centered
Assembly position / location: Any position
Subplate surface finishing: Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
ATOS Solenoid Valve SDHE-0711-X 230/50/60AC
There is no price at present, you can Request a Quote
People who bought this item also viewed
Parker Solenoid Valve E321G37
Daikin Solenoid Valve KSO-G03-3CB-20
KOGANEI Solenoid Valve F10LTA-PN
EATON Transformer PKZM0-10
Keyence Sensor AP-52ZA
Danfoss Solenoid Coil BJ240CS
SUMMER Overflow Valve EDG-01-C-T
Daikin Piston Pump VZ80C11RJBX-10
EALY Vane Pump 50T-07-FRL-X-10
PARKER Filter R.63213 QA-D5310
Danfoss Sight Glass SGI22S
SAMWHA Capacitor 250V 100UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder SCD125X200
KSK Oil SealTC(FKM)10X18X7
Eaton Moeller Circuit Breaker PLHT-C100
ADDA Fan AD0612HB-H93
Recent related posts
-
08/14/2020
The layout principle of Freon refrigerant pipeline
The main feature of Freon refrigerant is that it dissolves with the lubricating oil. Therefore, it must be ensured that the lubricating oil from each refrigeration compressor can return to the refrigeration compressor after passing through the condenser,
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/14/2020
What is an air compressor
The machine used to generate compressed air is also called compressed air machine, also called air compressor, or air compressor for short. The motor directly drives the compressor to make the crankshaft produce rotational movement, drive the connecting rod to make the piston produce reciprocating motion, and cause the cylinder volume Variety.
-
11/15/2022
How to Fix an Industrial Fan?
Industrial fans can effectively control the air circulation in industrial production workshops. However, industrial fans can also fail due to improper use and prolonged use.
-
09/06/2020
Dry air compressor sales, please keep these seven words in mind!
move】 Work does not raise idlers, and the team does not raise idlers. Go every day, not afraid of thousands of miles; Do it often, not afraid of everything.
-
08/16/2020
What to pay attention to when the refrigeration equipment is moved
Because the company needs to change the working environment, all the equipment of the company must be moved, and the refrigeration equipment in the disassembly and installation process requires staff with rich professional knowledge,
-
04/13/2023
15 Refrigeration System Components Structure, Function, Working Principle Diagram (1)
There are four main components in the refrigeration system, namely compressor, condenser, throttling device (such as capillary tube, expansion valve), evaporator.
-
08/16/2020
What are the tasks that water-cooled chillers need to perform regularly
When using a water-cooled chiller, due to environmental or water quality issues, which will affect the normal operation of the equipment, it is necessary to perform some work on the water-cooled chiller regularly to maintain a stable working state and reduce the occurrence of failures.
-
08/19/2020
How to identify qualified air source heat pumps
Air-source heat pumps have the characteristics of energy saving, environmental protection, safety and easy management. They are favored by many schools, hotels, and families.
-
06/13/2020
The brain hole is wide open! Japanese companies have introduced summer cooling masks,
The brain hole is wide open! Japanese companies have introduced summer cooling masks, which can be added to the refrigerator and frozen in the refrigerator after repeated use of the brain hole! Japanese companies introduced summer cooling masks, which can 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧