There is no price at present, you can Request a Quote
Series | H79B Series |
Refrigeration Application | High Temperature |
Type of Refrigerant | R407C |
Generation | Sixth Generation – Basic Standard Model Upgrade |
Family | Model B Reciprocating |
Nominal Capacity (BTU/Hr) | 28,000 BTU/Hr. "Upgrade" |
Motor Type | PSC Permanent Split Capacitor |
Motor Protector | Internal Line Break |
Electrical Characteristics | 220/240-1-50 |
Mounting Feet Dimension (Inches) | 7.5 x 7.5 |
Shipping cost is not included
The Bristol Compressor is high quality!
Bristol Compressor H79B28UABKA
There is no price at present, you can Request a Quote
People who bought this item also viewed
Mitsubishi Compressor NN33NAAMT
Sanyo Compressor C-RN113H3C
Copeland Compressor ZW34KA-PFS-582
Tecumseh Compressor RK5512Y-NA3A
Bristol Compressor H29B28UDBV
Bristol Compressor H73A563DBLA
Bristol Compressor H23A38QDBE
Bristol Compressor H22J253DBL
Sanyo Compressor C-SB261H6A
Copeland Compressor VR125KS-TFP-523
Danfoss Compressor SM090S4VC
Daikin Compressor 2YC36DXD
TRIAD Transformer F-14X
Danfoss Expansion Valve 068Z3346
Siemens Contactor 3RT1266-6AU36
JAMICON Fan KA1238H1B1N
ABB Electric Motor M2BAX80MA2
ENTEGRIS Filter WG2F02RR2
Danfoss Sight Glass SG6S
YORK Expansion Valve Coil EPF-32D86
PHILIPS Capacitor 151 68UF 400V
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COSEL Power Supply PMC100E-2
AirTAC Air Cylinder MARF63X75S
LIROJY Sensor LTC-3V1-Z
Recent related posts
-
06/25/2020
[Experience] Constant temperature and humidity box refrigeration system
[Experience] Constant temperature and humidity box refrigeration system Constant temperature and humidity box refrigeration system: 1 Two single-stage refrigeration system cascade refrigeration cycle; 2 Cascade refrigeration cycle of two-stage compression system;
-
09/10/2020
Working principle of okmarts.com air compressor water-cooled screw air compressor
There are many models of okmarts.com air compressors. Low pressure rotor. Electronic motor, the main components of LG-1.2/8LG-33/13 are: air filter. Low-pressure rotor intercooler. High-pressure rotors, rock drills, twin-screw air compressors, frequency conversion air compressors, after coolers, transmission parts, gear boxes, regulator control systems, safety valves and silencer shells, etc.
-
07/16/2020
Compressor failure and elimination
The compressor is the heart of the refrigeration system. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and discharges high-temperature and high-pressure refrigerant liquid to the exhaust pipe to provide power for the refrigeration cycle.
-
06/03/2023
What is a 2 Stage Air Conditioner: A Comprehensive Guide
Air conditioners have become an integral part of our lives, especially during the hot summer months. Over the years, air conditioning technology has evolved, and new systems have been introduced to offer better efficiency and comfort.
-
07/02/2020
Danfoss Miele Maneurop compressor MT40 market information
Danfoss Miele Maneurop compressor MT40 market information Meiyoule compressor model; Danfoss Meiyoule Maneurop compressor MT40; Meiyou MT40 horsepower: 3.3hp
-
04/27/2022
How to Test Your Surge Protection Device?
Surge protection devices protect our electronic equipment from the impact of surge and lightning which will occur without warning at any time.
-
07/02/2020
The heart of the compressor's refrigeration system
The heart of the compressor's refrigeration system If a person does not have a heart, it is equivalent to a dead person! The "heart" of a car is the engine. If there is no engine, the car is equivalent to scrap iron. The "heart" of the refrigeration system is the compressor. Now that summer is here, all kinds of air-conditioning, cold storage, chemical refrigeration processes, etc.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/14/2021
Comparison of three types of wall-mounted, vertical and central air-conditioning
In the summer, air-conditioning has become a must-have item. Now air-conditioning has a variety of styles. How to choose to make yourself more comfortable has become a problem that everyone needs to consider. How to choose wall-mounted machines, cabinets, 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐
-
06/14/2020
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!