Operation: double-acting, front and rear cushions
Operating pressure: 1 - 10 bar
Operating temperature: 0 - 80 degree Celsius (with dry air - 20 degree Celsius)
Bore diameter: 40mm
Stroke: 1200mm
CAMOZZI Air Cylinder 42M2N040A1200
People who bought this item also viewed
CAMOZZI Air Cylinder 61M2P063A0305
Festo Air Cylinder DSNU-16-25-P-A-S2
CHANTO Air Cylinder GXS16X10
AirTAC Air Cylinder TN20X20S
Festo Air Cylinder DFM-50-125-P-A-GF
Honeywell Actuator V4055B1104
SMC Proportional Valve ITV2030-213L4
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Schneider Sensor XMLP600BD12
TECO Servo Drive TSTA50D
Mitsubishi Servo Motor HF-105S-A48
THK Linear Guideway HSR85LR1UU
LNTECH Light Curtain SNA0820-W-F
Recent related posts
-
09/07/2020
Talking about Lubricant and Air Compressor
At present, the mainstream product on the air compressor market is the screw air compressor. Screw air compressor gradually replaces piston air compressor with its product characteristics.
-
09/09/2020
Choose four major indicators of frequency conversion air compressor
The frequency conversion technology was not originally born in the air compressor field, but with the development of the economy, all walks of life will inevitably develop in the direction of energy saving, environmental protection and low carbon.
-
09/08/2023
Air Source Heat Pumps Explained
Air source heat pumps (ASHPs) have emerged as a popular and eco-friendly alternative for heating and cooling homes.
-
04/25/2022
How to Install A Surge Protection Device?
Set power line surge protection device at the entrance of the line into the building, the interface of the lightning protection area and the place close to the protected equipment.
-
04/17/2024
Mitsubishi Servo Drive Fault Codes and Troubleshooting Methods
Mitsubishi servo system consists of servo motor, controller, and servo drive (also called servo amplifier), mainly including MR-J2S series, MR-J series, MR-H series, MR-C series, MR-J2 series, MR-J2S series, MR-E series, MR-J3 series, MR-ES series, MR-JE series, MR-J4 series, etc.
-
06/13/2020
The principle of air heat pump heating
In our lives, we often say "warm and warm to the house" to our guests. Compared with the cold and wet climate in the southern region, the cold in the northern region is dry and cold. The outdoor working temperature is minus ten or twenty degrees, which is 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់
-
02/17/2020
The principle of central air conditioning refrigeration
The principle of central air conditioning refrigeration The liquid Freon enters the evaporator through the capillary. The space suddenly increases and the pressure decreases. The liquid Freon will vaporize and absorb a lot of heat. The evaporator will become cold. The indoor unit fan will remove the indoor air from the evaporator. Blow through, so the cold air blows out from the indoor unit. Let's take a look at the cooling principle of the central air conditioner with the editor for your reference<img src="{{media url="magefan_blog/The_principle_of_central_air_conditioning_refrigeration.jpg"}}" alt="" />
-
08/02/2020
When air conditioners lack fluoride, five common leak detection methods will teach you who don’t understand!
When the air conditioner is lack of fluoride, the detection of leaks is the primary task of leakage repair. Today we introduce five common leak detection methods for you, namely fluorescent leak detection, soapy water leak detection
-
07/01/2020
Talking about the advantages of compressor enthalpy increasing technology
Talking about the advantages of compressor enthalpy increasing technology The air-jet enthalpy-increasing compressor adopts two-stage throttling intermediate air-jet technology, and uses a flash evaporator to separate gas and liquid to achieve an enthalpy-increasing effect. This compressor jet enthalpy increasing technology has many advantages, as follows:
-
08/20/2020
Operation method for filling freon in refrigeration system of high and low temperature box
The operation method of filling Freon in the refrigeration system of the high and low temperature box is as follows: 1, prepare a scale, weigh the freon cylinder, and record the net weight of the total weight Leon.