Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 14 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 208 A |
Circuit breaker size S2 for starter combination Rated current 14 A Nrelease 208 A screw terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For starter combinations
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 12.5?W
at AC in hot operating state per pole 4.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
Main circuit
number of poles for main current circuit 3
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 14?A
operating current
at AC-3
at 400 V rated value 14?A
operating power
at AC-3
at 230 V rated value 3?000?W
at 400 V rated value 5?500?W
at 500 V rated value 7?500?W
at 690 V rated value 11?000?W
operating frequency
at AC-3 maximum 15?1/h
Siemens Circuit Breaker 3RV2331-4SC10
People who bought this item also viewed
Siemens Circuit Breaker 3RV2011-0KA20
Siemens Circuit Breaker 3RV2011-0CA10
Siemens Circuit Breaker 3RV1011-1BA10
Fuji Circuit Breaker EW50RAGU-3P010
Siemens Circuit Breaker 3RV1011-0CA10
Siemens Circuit Breaker 3RV1011-1FA10
CHINT Transformer TSGC2-3
Delixi Contactor CDC1-12A
Schurter Fuse 0001.2531
Relpol Relay RM32N-3021-85-S024
UniOhm Resistor 0603WAF7503T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Circuit Breaker 5SY6501-7CC
COKERY Belt 2304-8YU
GS Battery 115E41L
SuperRed Fan CHA7012EBS-P-NF
Daikin Air Conditioner FEDAP36AA
Recent related posts
-
08/16/2020
What to pay attention to when the refrigeration equipment is moved
Because the company needs to change the working environment, all the equipment of the company must be moved, and the refrigeration equipment in the disassembly and installation process requires staff with rich professional knowledge,
-
06/24/2020
The reason why the air conditioner is not cooling
Occasionally encounter the problem that the air conditioner does not cool in life. Don't worry at this time. The reason for the air conditioner not cooling is not very complicated. After understanding the reason for the air conditioner not cooling, you can solve the problem by taking the right medicine.
-
01/25/2023
How to Maintain a Pressure Transmitter
In order to prolong the service life of the pressure transmitter and reduce the error, regular inspection and maintenance are recommended, such as weekly inspection.
-
08/11/2020
How to use central air-conditioning air-cooled water unit
One of the more prominent problems in the central air-conditioning water system is hydraulic imbalance. For some large-scale and more complex systems, there are usually many control loops.
-
08/14/2020
How to select the cooling fan in the floor heating and air conditioning system
For many dealers in the north, the heating end may be familiar, but they are not very confident in the cooling end. In our WeChat group, dealers often consult related questions.
-
02/19/2023
The Structure, Characteristics, and Notices for Use of Butterfly Valve
Butterfly valve consists of valve case and valve body. This valve, which is characteristic of rotatable disc or double plate, can be used to cut off water. Its axis of rotation is perpendicular to the direction of water flow.
-
06/13/2020
The refrigerator freezes thick Just one trick to fall off immediately!
After a long time, the refrigerator always has thick frost ' Every time you clean the refrigerator head It's a knife, a shovel, and a screwdriver. The refrigerator is still broken
-
08/06/2020
How to maintain the lubrication system of the chiller
In the operation system of the chiller, more attention is paid to the refrigerant circulation system, the chilled water circulation system and the electrical control system of the refrigerator. The lubrication system is often overlooked. As everyone knows, this system is also very important to the chiller.
-
06/13/2020
What are the possible reasons for the noise of the air-conditioning compressor
Compressor noise control is an extremely complex problem. What are the possible reasons for the noise of air-conditioning compressors? Only when the cause is found can the solution be found accordingly.
-
06/21/2020
Which refrigerator is better
The two cooling methods of the refrigerator are good. From the perspective of defrosting, the air-cooled refrigerator will perform better, because the air-cooled refrigerator uses forced air convection to cool the temperature. It reaches the expected temperature, and it is not easy to frost. The direct-cooled refrigerator absorbs heat by the evaporator to reduce the temperature, and it is easy to condense the frost.<img src="{{media url="magefan_blog/Which_refrigerator_is_better.jpg"}}" alt="" />