Circuit breaker 25 A A-release 20...25 A, N-release 400 A, for
transformer protection, screw connection, standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product for transformer protection
product type designation 3RV6
General technical data
size of the circuit-breaker S0
power loss W total typical 8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during transport -50 ... +80 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
20 ... 25 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 25 A
operating current
at AC-3
at 400 V rated value 25 A
operating frequency
at AC-3 maximum 15 1/h
Protective and monitoring functions
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 400 V rated value 25 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 400 V rated value 55 kA
response value current
of instantaneous short-circuit trip unit 400 A
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97 mm
width 45 mm
depth 96 mm
Siemens Circuit Breaker 3RV6421-4DA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV2011-0DA10
Siemens Circuit Breaker 5SL6220-7CC
Siemens Circuit Breaker 3RV1011-1FA10
Terasaki Circuit Breaker TD3M06
Siemens Circuit Breaker 3RV1011-1GA10
CHINT Transformer JBK5-40
Siemens Contactor 3RT2517-2GG20
Littelfuse Fuse SPF5
Shihlin Relay TH-P12PP 4-6A
IRC Resistor 2.5K
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NACHI Check Valve OCP-G03-B1-D-J50
Honeywell Flame Detector C7061A1079
UniOhm Resistor 1206W4J0270T5E
Recent related posts
-
06/14/2020
Hematemesis! Detailed explanation of the most comprehensive knowledge of relay protection
Hematemesis! Detailed explanation of the most comprehensive knowledge of relay protection When the power components in the power system (such as generators, lines, etc.) or the power system itself fails and endangers the safe operation of the power syste 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ѻ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識
-
09/07/2021
How to Test a Mass Flow Sensor?
The mass flow sensor, or air flow sensor is one of the important sensors of the electronic fuel injection engine.
-
09/10/2020
The management method of the air compressor room of the Red Fifth Ring
1. Choose a wide and well-lit place to facilitate the space and lighting required for the operation, maintenance and repair of the air compressor.
-
09/05/2020
What is the difference between single screw compressor and twin screw compressor
Single-screw and twin-screw manufacturing process of twin-screw is more complicated than single-screw in terms of structure, and the difference in service life and working efficiency is not very big,
-
07/22/2020
The fluorine refrigeration compressor is short of oil, how to add it?
When the compressor is running for a period of time, we can judge whether the compressor is short of oil by observing the oil glass. If the oil level in the oil glass is lower than half of the position, then we need to replenish the oil. This article introduces the oil replenishment method of small and medium-sized compressors.
-
06/14/2020
Is it necessary to install the fresh air system recommended during decoration Where are the people who have been eating ash for many years but are secretly happy this year
Is it necessary to install the fresh air system recommended during decoration Where are the people who have been eating ash for many years but are secretly happy this year Is it necessary for ordinary families to install fresh air system?
-
07/05/2020
Global HVAC Centrifugal Compressors Market 2020-2025 Report and Imapct of Coronavirus Pandemic
The “Portable Air Compressor” Market report considers the central point responsible for driving the development of the Snowblowers Industry, notwithstanding the key preventions and difficulties.
-
03/27/2023
Different Types of Refrigeration Compressors and Their Applications, Brands
The refrigeration compressor is the core and heart of the refrigeration system, and is an indispensable part of air conditioners, refrigerators, chillers, etc.
-
09/05/2020
What role does air compressor play in washing equipment and how to use it safely
Generally, you need to buy an air compressor to open a laundry room, so how big an air compressor should be configured in a general laundry room? This is the concern of the owner of the investment laundry room
-
09/08/2021
How to Test a Wheel Speed Sensor?
The wheel speed sensor is used to test the wheel speed of a car. For modern vehicles, wheel speed is essential.