COPAL Transmitter PA-930-302R-VC
People who bought this item also viewed
Huba Control Transmitter 506.932A03101
VECTOR Transmitter SDA-H1T1-20-W1
Danfoss Transmitter 060G2049
HANNA Conductivity Meter HI2030
Summit Pressure Gauge SUMMIT-608
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Air Cylinder ADVU-100-50-A-P-A
MINAMOTO Water Pump YHW750-40
CKD Air Cylinder MSTG-B-12-75
Recent related posts
-
08/08/2020
Calculation method of power cord size of industrial chiller
In the field of industrial chillers, how is the size of the power cord calculated? Let's go see how it works?<br></br> The working temperature is 30℃, and the current carrying capacity under long-term continuous 90% load is as follows:
-
07/09/2020
Know Reasons Why AC Compressor Market May See New Emerging Trends
Latest Study on Industrial Growth of Global AC Compressor Market 2019-2025. A detailed study accumulated to offer Latest insights about acute features of the AC Compressor market. The report contains different market predictions related to market size, revenue, production, CAGR, Consumption, gross margin, price, and other substantial factors.
-
09/05/2020
What is the composition of the often said air compressor station
For air compressors, especially screw air compressors, they cannot be used directly. It is also necessary to establish an air compressor station with corresponding post-processing equipment.
-
08/13/2020
Correct operation method and precautions of distribution box during cold storage installation
In the process of cold storage installation, the use of cold storage power distribution boxes is a very important content, but most people are not very familiar with the normal operation of cold storage power distribution boxes.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/13/2023
Hydronic HVAC System: A Comprehensive Guide
Hydronic HVAC systems are becoming increasingly popular as a more efficient and cost-effective way to heat and cool homes and commercial buildings.
-
10/12/2021
What are the Major Causes of Variable Frequency Drive (VFD) Damage?
The larger the setting value, the higher the gain and the greater the stiffness. Under the same frequency command pulse condition, the position lag will be smaller.
-
01/19/2024
Central Air Conditioning System: Types, Components, and Brands (including Mitsubishi Electric, Daikin, York, Carrier, etc.) (Part 1)
The various parameters of the central air conditioning system are basically outperformed by various wall-mounted units and cabinet units, but they have incomparable advantages in terms of space and appearance.
-
06/14/2020
Design and selection of compressor unit for mobile cold storage
1. Regardless of the brand selection of the compressor unit, it is determined according to the evaporation temperature of the active cold storage and the effective working volume of the cold storage. In addition, the condensation temperature of the frozen 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ
-
07/23/2020
Do you know the causes, hazards, treatment and prevention methods of compressor liquid strike?
Liquid hammer refers to the situation in which the refrigerant liquid or wet vapor is sucked into the compressor by the compressor due to the failure or insufficient heat absorption and evaporation of the refrigerant, which is called liquid hammer.<br></br> <br></br>