Body Type | ZF Compressor |
Product Type | Scroll Compressors |
App | LL |
Capacity BTU/HR | 12600 |
EER BTU/WH | 4.5 |
Freq | 50Hz |
Phase | 3Ph |
Voltage | 200-220 |
Copeland Compressor ZF09K4-TFW-265
There is no price at present, you can Request a Quote
People who bought this item also viewed
Copeland Compressor ZR61KCE-TFD-523
Mitsubishi Compressor RHV135FCC
Toshiba Compressor PA200X2CS-3MUU
Copeland Compressor ZB76KQE-TFD-550
Copeland Compressor VR144KSE-TFP-522
Copeland Compressor ZR42K3-TFD-522
Copeland Compressor ZR36KH-TFD-522
Copeland Compressor ZRD125KCE-TFD-265
Hitachi Compressor 303DHV-47B2
Tecumseh Compressor TFH55524F
Daikin Compressor JT95BH-Y1L
Daikin Compressor JT160BCBY1L
CHINT Transformer NDKG-700
Siemens Contactor 3RT2517-1BW40
Ebmpapst Fan RL90-18/50/14
ASLONG Electric Motor PG22-2230
MAHLE Filter LX5177
EMERSON Sight Glass AMI-1SS5
SAMYOUNG Capacitor 250V 820UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder MAJ25X35-50S
AirTAC Air Cylinder SC125X235S
NACHI Vane Pump VDR- 11A-1A2-1A2-22
AirTAC Air Cylinder SILF160X125S
ASHCROFT Transmitter IXLdp +/-15"WC
Sanyo Compressor C-SB453H6A
Recent related posts
-
07/23/2020
Analysis of common failure causes of hermetic refrigeration compressors
1. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.<br></br>
-
06/14/2020
Do you know the two methods of evacuating the refrigeration system?
Do you know the two methods of evacuating the refrigeration system? Vacuuming is an indispensable important process before charging refrigerant in the production or maintenance of refrigeration equipment. The process of removing the non-condensable gas a 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥
-
06/29/2020
Several causes of compressor burning
-
09/06/2020
Application of High Pressure Soft Start on Compressor Load
Abstract: The high-voltage and high-power motor has a relatively large impact on the load and the power grid when starting. Thyristor series high-voltage soft starters are widely used for their superior starting performance and other advantages.
-
08/11/2020
Common practice of oil return design in refrigeration system
When the condenser is installed higher than the compressor, a U-shaped bend is required at the intake pipe of the condenser to prevent oil from returning to the exhaust side of the compressor during shutdown and also help prevent liquid refrigerant from the condenser
-
09/11/2020
Several Improvements on the Easy Failure Points of Air Compressor
The original compressor has poor cooling effect and low efficiency. The improvement method is to introduce the water that enters the primary and secondary cylinders and the intercooler directly from the main pipe to the water collecting funnel after cooling.
-
07/18/2020
How to protect the refrigeration compressor
Safety operating rules for Freon refrigeration compressor units in cold storage Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
08/13/2020
How to take out the ammonia refrigerant in the refrigeration system
First, prepare all the tools and emergency supplies, such as ammonia irrigation, a certain number of ammonia bottles, connecting pipes, fitter tools, gas masks, rubber gloves, first aid medicine, etc.
-
06/23/2020
The air conditioner suddenly stopped cooling.
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
-
05/03/2022
How to Deal With 6 Common Faults of Contactor?
Cause: The short-circuit ring of AC contactor is broken or the end faces of dynamic iron cores and static iron cores are uneven; Skewed or dirty.