There is no price at present, you can Request a Quote
Copeland Compressor ZH150KCE-TEJ-524
There is no price at present, you can Request a Quote
People who bought this item also viewed
Mitsubishi Compressor KB122VPD
Mitsubishi Compressor RS2527ESH14 ALA201A025
Sanyo Compressor C-7RVN153HOW
Tecumseh Compressor RKA5510CXA
Copeland Compressor ZP182KCE-TFD-522
Copeland Compressor CR62KQM-TFD-202
Copeland Compressor ZR34KH-TFD-522
Copeland Compressor ZR250KC-TWD-522
Sanyo Compressor C-SBP160H38C
GMCC Compressor DA150S1C-20FZ
Toshiba Compressor PH290X2C-8FTC1
GMCC Compressor ASM106E2VEZ
TRIAD Transformer F-3117X
Schneider Contactor LC1D18JL
SUNON Fan MG55150V1-Q020-G99
ZHONGDA Electric Motor Z3D20-24GN
AirTac Filter BF4000
Danfoss Sight Glass SGP16SN
Hitachi Expansion Valve Coil EPF32
VISHAY Capacitor MAL204868101E3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Honeywell Switch AML21HBA3AB
KMC Industrial Chain silver white X9
PULSAFEEDER Diaphragm Pump LEK7SB-KTC3
Festo Air Cylinder DNG-32-50-PPV-A
Recent related posts
-
07/23/2020
Analysis of Overheating Failure of Refrigeration Compressor
The main reasons for the overheating of exhaust temperature are as follows: high return air temperature, large heating capacity of the motor, high compression ratio, high condensation pressure, and improper refrigerant selection.<br></br> <br></br>
-
07/30/2020
FAQs on refrigeration compressors, do you know these
Impurities entering the friction surface of the moving parts of the compressor pump body will cause abnormal scratches and wear. Impurities entering the solenoid valve, expansion valve, control valve, capillary tube and stop valve in the refrigerator system will block the valve hole or The valve is not closed tightly and fails.
-
03/02/2023
The Types of Air Cylinder and Notices for Use
Air cylinder is a tube-shaped metal mechanical part that guides the piston to do linear reciprocating motion in its insides.
-
12/21/2023
AC Fan Won't Turn off (Troubleshooting Guide)
The air conditioning system can be a true lifesaver during sweltering summers and chilling winters, providing comfort and respite from extreme temperatures.
-
01/14/2021
Comparison of three types of wall-mounted, vertical and central air-conditioning
In the summer, air-conditioning has become a must-have item. Now air-conditioning has a variety of styles. How to choose to make yourself more comfortable has become a problem that everyone needs to consider. How to choose wall-mounted machines, cabinets, 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐
-
08/11/2020
How to choose a dedicated central air conditioner in a supermarket
Everyone should be familiar with central air-conditioning. It is widely used in our homes and some public places. It can adjust the temperature in the house very well and can bring good ventilation effects.
-
08/11/2020
How to maintain the lubrication system of the chiller
In the operation system of the chiller, more attention is paid to the refrigerant circulation system, the chilled water circulation system and the electrical control system of the refrigerator. The lubrication system is often overlooked. As everyone knows, this system is also very important to the chiller.
-
09/11/2020
How to use empirical methods to inspect rolling bearings
How to use empirical methods to inspect rolling bearings Some operators lack the experience in identifying rolling bearings and continue to use them as long as they see no obvious damage to the rolling bearings, causing serious failures later. Some people only need to remove the rolling bearings and replace them without inspection.
-
09/09/2020
Compressor companies have caused the misunderstanding of killing, how many tricks have you hit
In recent years, many machinery manufacturing companies, including the compressor industry, have suffered unprecedented tests. Some are not adaptable due to the transformation of the economic system, and there are also "secret injuries" from the company’s own business strategy.
-
07/31/2020
Multi-online display FC, FL, FE fault processing method
Outside machine LED3 double 8 indicator light is on and displays: FC, FL, FE. When the indicator light of the external mainboard and the line controller fail, the following figure will be displayed: