There is no price at present, you can Request a Quote
Series | AFB Series |
Fan Type | Axial Fan |
Size / Dimension | 60 mm SQUARE |
Bearing Type | Ball |
Voltage - Rated | 48 VDC |
Air Flow | 27.5 CFM (0.770m³/min) |
Noise | 40.0dB(A) |
Power (Watts) | 3.84 W |
Speed (RPM) | 5000 RPM |
Termination | 3 Wire Leads |
Operating Temperature | 14 ~ 158°F (-10 ~ 70°C) |
Approval Agency | CE, CSA, UL, VDE |
Weight | 0.176 lb (80.00 g) |
Delta Fan AFB0648HH-R00
There is no price at present, you can Request a Quote
People who bought this item also viewed
ADDA Fan AD0412HB-J93
Ebmpapst Fan W2D250-EA26-21
Delta Fan BFB0724H-F00
Delta Fan AFB0912DH
Delta Fan AFB1212EJ-01
Delta Fan BUB0612H-SE01
SUNON Fan AB1123-HBT.GN
ORION Fan OD5010-12MB
ADDA Fan AB1012MX-B03
SUNON Fan KDE0504PFB3-8
Bristol Compressor H26D573BBH
Fuji VFD Frequency Converter FRN7.5P9S-4CE
OMRON Power Supply S8FS-C03515J
Block Transformer VB 3,2/1/15
Siemens Circuit Breaker 3VU1640-0MR00
Siemens Contactor 3RT2617-1BF43
PARKER Filter G03357
AZBIL Relay AUR450C8225000
EACO Capacitor STS 630V 0.47UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ABB Circuit Breaker S201M-B2
Recent related posts
-
09/05/2020
The pipeline is not working well, and the compressor is exhausted
Many users have invested a lot of energy and money in the selection, operation and maintenance of compressor equipment, but due to negligence on the compressed air pipeline, a lot of waste has been caused.
-
07/19/2020
Advantages of adding economizer to screw chiller
The temperature control range of the standard screw chiller is 3~35℃, and the efficiency is significantly reduced when operating under lower temperature conditions. In order to meet the temperature requirements of more industries for chillers, make the single-stage screw compressor work according to the two-stage refrigeration cycle and achieve the effect of energy saving, an economizer can be added to the unit.
-
06/28/2020
Hitachi compressor model sample parameters
Hitachi compressor model sample parameters W Cooling Capacity Btu/h COP (A) Compressor (B)
-
09/08/2020
Introduction of micro heat regeneration adsorption dryer
The non-thermal regeneration suction dryer uses the compressed air pressure change, adsorption under high moisture pressure, and desorption under low moisture pressure to regenerate the adsorbent.
-
10/19/2023
Refrigerated Display Case: Everything You Need to Know
Refrigerated display cases are essential equipment in various industries, most notably in the food and beverage sector. They provide a visually appealing and hygienic means to showcase perishable items, such as chilled drinks, fresh produce, dairy products, and delicatessen.
-
06/16/2022
How to Install a HMI and 4 Common Failures?
In nearly any assembly line, or manufacturing plant, employees work with touchscreens every day. This link between man and machine is a Human Machine Interface, or HMI for short.
-
09/21/2020
Working principle and usage method of motor bearing grease
Working principle and usage method of motor bearing grease The lubrication of the motor bearing relies on the lubricating oil that is precipitated when the three-dimensional fiber network structure in the grease is broken under the action of shear, forming a layer of lubricating film on the rotating elements of the bearing, the bearing seat and the bearing race for lubrication Effective.
-
01/05/2021
Real Gas Model for an Electric Swashplate Refrigeration Compressor
Real Gas Model for an Electric Swashplate Refrigeration Compressor Author links open overlay panelMohammadArqam1Dzung VietDao1AmirJahangiri2MarkMitchell2PeterWoodfield1 1 School of Engineering and Built Environment, Griffith University, Australia 2 U 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
12/13/2023
R410a VS R134a: Comparison of Commonly Used Refrigerants in Data Centers
At present, data centers mainly use two types of refrigerants. One is R410a, which is mainly used in small or medium-sized data centers with air conditioning cooling capacity of 300-400 KW.
-
09/10/2020
Causes of Compressor Common Failures and Countermeasures Analysis
Abstract: During the operation of the compressor, some failures and even accidents will inevitably occur. A fault refers to an abnormal condition that occurs during the operation of the compressor, which can be restored to normal operation once the compressor is eliminated, while an accident refers to a damage situation. The two are often related, and if the fault is not eliminated in time, it will cause a major accident.