Series | ECMA Series |
Product | AC Servo Motor |
Rated Voltage | 220V |
Rated Speed | 3000 r/min |
Encoder Type | Incremental encoder |
Encoder Resolution | 20-bit |
Motor Frame Size | 80mm |
Output | 750W |
Brake | Without Brake |
With Oil Seal | No |
Shaft Type | Keyway |
Shaft Size | Standard Shaft Diameter |
Delta Servo Motor ECMA-C10807ES
People who bought this item also viewed
Yaskawa Servo Motor SGMAS-12A2A4B
Delta Servo Motor ECMC-EW1310RS
Delta Servo Motor ECMA-E21315ES
Delta Servo Motor ECMA-C11020ES
Delta Servo Motor ECMA-C21010FS
Panasonic Servo Motor MSMA012A1E
Sanyo Denki Servo Motor P50B08075HXS6L
Yaskawa Servo Motor SGMAH-07DAA61D-OY
Panasonic Servo Motor MDME302GCH
Fuji HMI Industrial Touch Screen V708SD
Johnson Controls Actuator M9206-GGB-2S
ZIPPY Power Supply MPW-6200F
Delta PLC Analog I/O Module AH08AD-5A
MITSUBISHI Spindle Amplifier MDS-A-SPJ-37
Mitsubishi Input Output Module A1SX42-S1
TYCO Relay FW5A1201G01
YUASA Battery S-95-EFB
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
DINKLE Relay RE-3704
Festo Solenoid Valve VMPA1-M1H-E-S-M7-PI
BANDO Belt T5-990-27
Banner Sensor SM2A312CV
Recent related posts
-
06/14/2020
11 common protection devices for refrigeration compressors
11 common protection devices for refrigeration compressors When the compressor is running, some abnormal conditions may occur, such as: the discharge pressure is too high
-
08/11/2020
Selection knowledge of screw chiller
Screw chiller is a large-scale industrial refrigeration equipment. It is widely used in central air-conditioning and large-scale refrigeration industry. It plays an important role in refrigeration, cooling and cooling.
-
06/14/2020
11 common problems in refrigeration compressors, do you know these
11 common problems in refrigeration compressors, do you know these 1.Why control the impurity content and moisture content of the compressor and air conditioning system?
-
06/14/2020
The air conditioner does not use electricity, the minimum cooling is -25 ℃, is it true
The air conditioner does not use electricity, the minimum cooling is -25 ℃, is it true Air-conditioning has become an indispensable configuration for everyone.
-
07/12/2022
Differences between Single Mechanical Seals and Double Mechanical Seals
Pumps work hard to distribute fluid throughout elaborate systems. As a failsafe against leakage, pumps include one of two parts: packings or mechanical seals.
-
06/13/2020
Analysis of the current status of refrigeration compressor technology development
Analysis of the current status of refrigeration compressor technology development
-
06/14/2022
How to Select a HMI?
There are three basic types of HMIs: the pushbutton replacer, the data handler, and the overseer.
-
06/30/2020
You should know the normal working condition of the compressor in the cold storage
You should know the normal working condition of the compressor in the cold storage 1. The suction temperature of the compressor should be 5-15℃ higher than the evaporation temperature.
-
08/11/2020
Common practice of oil return design in refrigeration system
When the condenser is installed higher than the compressor, a U-shaped bend is required at the intake pipe of the condenser to prevent oil from returning to the exhaust side of the compressor during shutdown and also help prevent liquid refrigerant from the condenser
-
07/31/2020
What are the specific operation methods for maintenance of screw compressors in cold storage
Before the cold storage screw compressor must be overhauled, if possible, unload the slide valve to the "0" position, shut down normally, and cut off the power supply.