Part Number | - |
Seal | Nitrile Seals |
Pump Type | Single Vane Pumps |
Series | V10 Series |
Cover Type | Standard cover |
Mounting | Flange, 2 bolt SAE A size |
Inlet Port Connection | 1 5/16–12 straight thread |
Rated Capacity | 3.79 l/min (1 USgpm) |
Outlet Port Connections | 1 5/16-12 straight thread |
Shafts | Straight, keyed |
Pressure port positions | 90°CCW from inlet |
Rotation | Left hand (counterclockwise) |
Geometric Displacement,cm ³ /r (in ³ /r) | 3.3 (0.20) |
Maximum Pressure,bar (psi) | 172 (2500) |
Maximum Speed | 4800 rpm |
Minimum Speed | 650 rpm |
Weight | 4.5 - 6.8 kg (10 - 15 lb) |
Eaton Vickers Vane Pump V10-1S1S-1B20L
People who bought this item also viewed
OUYIPU Vane Pump IVP-30C-10
Eaton Vickers Vane Pump 35V-25A-1D22R
Eaton Vickers Vane Pump 25V-12A-1A22R
Eaton Vickers Vane Pump 25V-17A-1A22R
Eaton Vickers Vane Pump 35V-30A-1B22R
Camel Vane Pump VCM-SF-30A-20
TOYOOKI Vane Pump HVP-VCC1K-F3030A2A2
Yuci Vane Pump PFED-42056-005-1DT
HONGYI Vane Pump 20V3A-1B22R
CROUZET Check Valve 81529005
SUN Overflow Valve PPJB-8DN
Rexroth Piston Pump A2FO180/61R-PZB05
ECKERLE Gear Pump EIPH2-008RK03-1x
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Transformer MT0350B
EALY Vane Pump VGPE-F30D-PA-9T
Baumer Sensor IFFM 20P17A3/KS35PL
KSK Oil SealTC(NBR)150X180X13
Festo Solenoid Valve MN1H-5/3B-D-1-S-C
Recent related posts
-
03/07/2021
AC servo driver wiring precautions
For signal line and encoder input line, please use shielded wire. Wiring length: the length of signal line from NC to AC servo driver is less than 3m, and the length of input line from AC driver to encoder is less than 20m. The ground wire should be thick wire as far as possible. According to the third grounding standard (grounding resistance < 100 Ω), one point grounding method should be adopted to connect the ground wire. If the motor and the machine tool are insulated, the motor should be grounded.
-
06/14/2020
Haikou exploded, the central air conditioner was back
Haikou exploded, the central air conditioner was back, was it wrong Since 2020, the safety of the use of central air conditioning has been widely concerned. From the clustered infections in closed places during the epidemic to the explosion accident in H 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱
-
01/11/2022
Case Studies of How to Replace a Compressor in Refrigerator (Part One)
Some mechanic maintenance workers have noted that there could be some other faults after changing the compressor for the refrigerator. What are the causes? This article will give the reasons by introducing several cases.
-
12/24/2021
High Temperature Mulfunction of Screw Compressor and Solutions
Ambient temperature may not be the main cause of high temperature shutdown, but it is often the inducement of compressor high temperature shutdown.
-
07/28/2020
Simple and clear-graphic analysis of central air conditioning cleaning
Simple and clear-graphic analysis of central air conditioning cleaning<br></br> Three steps for central air conditioning cleaning: air outlet first, air return, focus on cleaning the filter<br></br> 1. Clean the air outlet<br></br> Adjust the swing leaf of the air outlet panel of the indoor unit to a level, and wipe the outer air outlet of the room with a clean towel. If you want to clean the inner louver, you need to remove the air outlet and clean it.
-
09/14/2020
Several PTA equipment process routes and equipment air compressor technology
PTA is the abbreviation of Purified Terephthalic Acid. PTA is the basic material for the production of polyester fiber and packaging industry, and the main raw material for the chemical fiber industry.
-
09/09/2022
Permanent Magnet DC Motor: Types, Application, Selection Principle (1)
A <strong>permanent magnet DC motor</strong> (PMDC motor) is a type of DC motor that uses permanent magnets to create a magnetic field.
-
07/15/2020
ZP49KSE-TF74.1 horsepower 60Hz (R410A) air conditioner Emerson Copeland compressor
Today I want to introduce the Emerson Copeland compressor ZP49KSE-TF7, which is suitable for R410A refrigerant at 60Hz three-phase electric air conditioner. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 4.1 hp. Other technical parameters can be downloaded from our company's website to download the product manual.
-
08/11/2020
5 key points of central air conditioning installation
Central air-conditioning installation is a very high-end technology. I don't dare to install central air-conditioning without a few years of experience.
-
06/14/2020
11 common problems in refrigeration compressors, do you know these
11 common problems in refrigeration compressors, do you know these 1.Why control the impurity content and moisture content of the compressor and air conditioning system?