Type | Axial fans |
Series | W2G110 |
Voltage - Rated | 48VDC |
Size / Dimension | Square - 119mm L x 119mm H |
Width | 38.00mm |
Air Flow | 156.0 CFM (4.37m³/min) |
Bearing Type | Ball |
Fan Type | Tubeaxial |
Noise | 54.0dB(A) |
Power (Watts) | 5.9 W |
Termination | 2 Terminals |
Approval Agency | CSA, UL, VDE |
DC fans
Fully integrated commutation elctronics
119*119*38mm
Ebmpapst Fan W2G110-AM41-31
People who bought this item also viewed
Ebmpapst Fan G2D120-AA22-25
TWYX Fan RB-41D-A3
Ebmpapst Fan W2E130-AA03-01
Ebmpapst Fan 4412M
Ebmpapst Fan 4312/2
Ebmpapst Fan K2E250-AH34-06
Delta Fan GFC0412DS-DA2J
Servo Fan D0925C12B4AS-00
SUNON Fan MF60090V1-B080-G99
KAKU Fan KA1238HA
Mitsubishi Compressor RM-B5112M
COSEL Power Supply PBA50F-24-CG
CHINT Transformer NDKG-50
Shilin Contactor S-P25T
PARKER Filter 938786Q
EMERSON Sight Glass HMI-STT9
PHILIPS Capacitor 132 470UF 16V
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Yaskawa Servo Motor SGMGV-20ADA61
Beckhoff Terminal Box Module IP2400-B730
Recent related posts
-
06/14/2020
What are the causes of frost in refrigeration compressors
1. The opening of the thermal expansion valve is too large, or the installation of the temperature sensor is incorrect and the fixing is not firm or loose. The main reason is that the temperature sensor may feel the temperature too high in this case, resu 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž
-
01/17/2023
How does Variable Valve Timing Work?
The valve timing system of a traditional engine is a mechanical system in which the valve timing (i.e., valve opening and closing) remains unchanged.
-
06/30/2020
What are the causes of compressor overheating
What are the causes of compressor overheating Some causes of compressor overheating: high return air temperature, large motor heating capacity, high compression ratio, high condensing pressure, and improper refrigerant selection.
-
05/01/2023
What are Refrigeration and Air-Conditioning Compressor Heaters Used For
The compressor heater (oil heater, crankcase heater, compressor heating belt) is a part of the refrigeration compressor.
-
06/22/2020
Working principle of steam compressor_steam compressor application
Working principle of steam compressor_steam compressor application Working principle of steam compressor After the steam is filtered by the filter, clean steam then enters the host cavity through the intake valve, and the volume of the cavity changes from large to small to compress the steam. The volume of the cavity is changed by the rotor rotating under the drive of the motor. <img src="{{media url="Working_principle_of_steam_compressor_steam_compressor_application.jpg"}}" alt="" />
-
08/09/2020
How to deal with the refrigerant leakage of precision air conditioner in computer room
As we all know, the power density of equipment in the computer room is high, so the volume heat is high. The computer room for exchange and data still needs to be continuously cooled by air-conditioning compressors to meet the environmental temperature requirements of communication equipment.
-
08/13/2020
How to judge the chilled water flow of the chiller
Generally speaking, when buying a chiller, you will have questions. I don't know how to judge the chilled water flow rate of the chiller? From what aspects should the chiller water flow be considered? Today, the editor of okmarts.com will share with you fPﰨ2 䀀 湠癐
-
01/09/2021
Be sure to understand these before installing a new fan
The most troublesome thing: the new fan requires indoor and outdoor air exchange, which requires opening holes on the wall or glass. The diameter of the holes in the market is basically concentrated on 150mm\120mm\110mm\100mm.
-
08/11/2020
Radiator heating system riser pipe installation and precautions
1. Standpipe installation of radiator heating system:<br></br> 1. When arranging the system riser, it should be matched with the use requirements of the building, the heating system diagram, the layout of the radiator, etc.. It is necessary to save pipes and facilitate installation and maintenance.
-
08/23/2020
What to do if the air conditioner protection light is flashing and not cooling
In the entire home repair industry, what can quickly arouse the attention of users is the previous TV repair, and the current air conditioning repair is also one.