Ebmpapst Fan W3G910LV12D1
People who bought this item also viewed
ADDA Fan AD0412HB-J93
Nidec Fan C35129-51API
Servo Fan G1751M48B8ZZ-00
Ebmpapst Fan R2E140-AS77-37
Ebmpapst Fan 4606N
Ebmpapst Fan 4214NH
Ebmpapst Fan A5E01052493AE
ADDA Fan AB06505HX07K301
Sanyo Denki Fan 109S078UL
ORION Fan OA109AP-11/22-1WB
Ebmpapst Fan QG030-353/14
Hitachi Compressor SH307RV-C8LU
LW Power Supply TPR-6420D
CHINT Transformer SG-40
Fuji Contactor SC-E3PH-C
MAHLE Filter KL1107
EMERSON Sight Glass AMI-1SS9
Beckhoff Module KL3044
Nichicon Capacitor FG 50V 2.2UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Copeland Compressor RF41C5E-CAZ-252
Autonics Rotary Encoder ENA-250-2-N-5
GSD Mechanical Seal EA560-2''
Recent related posts
-
12/22/2021
Five Pros of Refrigeration Compressor of Mitsubishi Electric
For refrigeration products, high efficiency and energy saving are the constant pursuit and breakthrough of technology.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
04/08/2024
8 Well-known Chinese Servo Motor/System Manufacturers
At present, there are more than 20 large-scale servo brands in China. Some of the products of these manufacturers have outstanding quality and performance, which show a certain degree of independence and innovation. These products now have a certain position in the mid-to-high-end market.
-
02/01/2024
Duct Booster Fan Application and Installation Guide
A duct booster fan (duct fan, booster fan) is a mechanical device whose main function is to increase the pressure of the gas in the air duct, thereby increasing the air volume and speed.
-
06/14/2020
Refrigeration compressor installation conditions and precautions
The selection of the installation site is ignored by the staff. Often the compressor will be found at random after it is purchased and used immediately after piping.
-
07/26/2020
The return pipe and compressor of cold storage are frosted. Why?
Yesterday, the reason for the frosting of the air-conditioning compressor and the compressor was released. Someone left us a message. I hope we can analyze the reasons for the frosting of the return pipe of the cold storage and the compressor.<br></br>
-
03/13/2023
Classification of Water Pump
Classification of Water Pump
-
07/09/2020
Impact of COVID-19 on Global Gas Powered Air Compressors Market Outlook and Possibilities (2020-2029) || Hitachi, NorthStar, Rolair Systems
Study accurate information about the Gas Powered Air Compressors Market: Statistics, Facts and Figures, Growth Overview, Size, Major Players, Swot Analysis Industry Outlook and Regional Analysis, and Forecast To 2029. Extensive Study on Impact of the novel coronavirus (COVID-19) pandemic on the Gas Powered Air Compressors market originally based on Current Research of Potential Growth Challenges and Future Progress till 2029.
-
06/14/2020
What to do if the screw chiller compressor is damaged
The compressor is the core component of the chiller. Damage to the compressor is a serious fault that needs to be dealt with in time, otherwise the chiller will not work. Today, the editor will introduce the knowledge and process of handling damaged screw 器2 䀀
-
07/27/2020
Content overview: compressor operating principle, A/C switch function, difference between internal and external circulation air intake system
The season of using cold air-conditioning is coming: how to use the A/C switch and the operating principle of the car air-conditioning system. These two points are necessary for car users to understand some knowledge; especially the switching method of internal and external circulation, in different modes The ability of air purification and filtration will vary greatly. Let's talk about the air conditioning system of a car.<br></br>