They feature 24 V to 48 V d.c. sensor less motors with a built-in drive that is fully compatible with our range of TAG and TIC controllers.
They are available pre-set for either 80 W or 160 W maximum power, the former enabling use with our 100 W TIC controllers are also recommended for pumping Argon, but with a longer ramp time to full operating speed.
Edwards Vacuum Pump NEXT300T
People who bought this item also viewed
NASH Vacuum Pump 2BV2070ONC002P
NASH Vacuum Pump 2BV2061ONC022P
YIDA Magnet Pump XND-6R
ALL-FLO Diaphragm Pump A100-BAA-GGPN-B30
YOTEC Water Pump 40-125
Hiige Mechanical Seal 3A1-001-19-aeE03
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
EALY Vane Pump VOP-204-F-RV-C
Siemens Transmitter 7ML5630-0CH00-0FA0
Banner Sensor QS18RNWLPC1
MINDMAN Air Cylinder MCFA-12-32-5
Recent related posts
-
06/13/2020
Is PVC or PE good for domestic fresh air system pipes
Is PVC or PE good for domestic fresh air system pipes Fresh air system is a category of light equipment and heavy design. Fresh air equipment is highly dependent on design and construction.
-
08/14/2020
Effective means to reduce the resistance of condenser heat transfer system
To ensure that the condenser has a higher heat transfer coefficient, it is necessary to reduce the resistance in the system. There are three ways to achieve this goal.
-
08/09/2020
The meaning of pipe diameter De, DN, d, ф
The meaning of pipe diameter De, DN, d, ф<br></br> The respective ranges of De, DN, d, ф<br></br> De-- PPR, PE pipe, polypropylene pipe outer diameter<br></br>
-
08/07/2020
Working principle of frequency converter
Inverters can be divided into voltage type and current type inverters.<br></br> Voltage type is an inverter that converts the DC of a voltage source to AC. The filtering of the DC loop is a current type that converts the DC of the current source to A
-
08/13/2020
Water-cooled chillers need to be cautious when choosing cooling towers
In many special use environments, companies need to apply water-cooled chillers. Because water-cooled chillers need the help of cooling towers during operation, they need to follow the
-
06/20/2020
The role of condensing pressure regulating valve
Condensing pressure regulating valve When the refrigeration device is running, if the condensing pressure is high, the compressor discharge temperature will rise; the compression ratio will increase; the cooling capacity will decrease; The higher the condensing pressure, the greater the above adverse effects. The high condensation pressure is mainly seen in summer. <img src="{{media url="The_role_of_condensing_pressure_regulating_valve.jpg"}}" alt="" />
-
07/13/2020
Danfoss expert analysis! Causes and troubleshooting of compressor start-up with liquid
Identify the authenticity of Danfoss compressors, solenoid valves, expansion valves, and filters Danfoss T2 valve true and false comparison:
-
09/04/2020
The difference between air compressor inverter and soft starter
Soft starter concept Soft start (also known as soft starter, motor soft starter, soft starter) Soft start is a novel motor control device that integrates motor soft start, soft stop, light load energy saving and multiple protection functions.
-
08/07/2023
Why Does My Heat Pump Have Frost on It (Causes and Prevention)
Heat pumps are an excellent way to keep your home warm in the winter and cool in the summer, but they can encounter problems from time to time. One common issue that homeowners may experience is frost buildup on their heat pump heat pump frosting up.
-
06/13/2020
Working principle of screw compressor
Working principle of screw compressor The screw compressor cylinder is equipped with a pair of interlocking helical male and female rotors. Both rotors have several concave teeth, and the two rotate in opposite directions.