There is no price at present, you can Request a Quote
We can also provide the following models
TERE 8RCA-03
BASB 1-1/4SW100-05
TMR 4FAA-09
AFAE 3RW15-06
LCLE 8A-61G
HFNSC 1SAA-09
TJLNB 6-1/2FAA-07
HFNE 1-3/4MA-09
NDE 1ZAA-02G
TRAE 14RW-01GB1
ANCEB 1/4MW45-04
TIE 3NW100-04G
TJRB 14HAA-07
LCL 9B-11
AACB 4BW45-04
TIEB 10NAA-31G
TIEB 3RC-50
HFE 1/2FZ-05
LCL 4C-99G
TERNEB 8FW55-06
TJLB 25FC-03
HFEC 8-1/2BAA-01
HFESC 3HW45-03
AFA 1/5HW-10G
ANE 1HW-08
TIRNB 7-1/2FW-09
ACPE 5-76B1
TCL 75HW-02
HFESC 1/2DW35-09
AACEB 3/4SAA-07
THRNE 45HAA-06
NDE 8ZAA-42G
HFESC 2FW45-06
ACP 8-29
HFSC 10HAA-08
HFNSC 1-1/2HA-07
AFA 1-1/4NW-10GB1
HFNS 1-1/2HW45-03
TIE 10NW-34B1
TJLNE 3HZ-09
TCLNE 1-1/2MW100-03
HFSC 1/5DW-09
BA 2-1/4RW-04
TCLB 20FC-05
TCLN 2HWS-01
TIEB 5MCA-38GB1
AACB 2HCA-01
AFA 1-1/4NW-09
TIRN 5HCA-05
AFA 1/4RW45-03B1
LCLE 2A-31B1
HFESC 1/4BAA-03
TIRE 35HC-01
TRAE 40SW90-06B1
TJR 1FW-08
ANCE 1/2BW45-07
TRAE+ 40MW-05
TRAE+ 20NW-04GB1
AAC 1/5BC-05
HFC 1-1/2HZ-05
AAEB 1TW-07
TJRNE 26HC-08
ANEB 1-1/2TCA-06
TJLE 22HC-08
TRAE+ 20PW90-07GB1
HFEC 3TCA-08
HF 1/4FCA-06
TERB 20FWS-09
AFA 1-1/4SZ-06G
HFNSC 3-1/2SA-09
AFA 3FW55-08
BNB 6NW100-05
HFS 1DA-01
AAB 2-1/2DC-07
TIE 10PAA-09G
HF 15HC-09
TCLN 3RC-07
TIE 3RW75-12G
BASB 4HW100-01
AAEB 2-1/4SCA-05
TRAE 15HW85-03B1
HFNEC 3-1/2BZ-02
BNEB 1/4PCA-02
TCLE 11FC-04
AA 1-1/2BW100-07
HFEC 3/4DC-09
HF 1-1/4TW100-08
HFES 1-3/4MAA-06
TJRE 6-1/2FW-08
TERNE 10HWS-10
BA 1/4PW100-05
TERNB 1FW-03
TRAE+ 12FW100-08
AFA 2RC-09GB1
HFNES 12HA-09
LCL 9A-02
HFNES 10HZ-04
TJRNB 11HCA-04
TRAE 30NAA-01GB1
ACP 3-79
TRAE 35FC-10G
THRB 45HZ-09
AFAE 1/4PW55-10GB1
LCLE 3A-83
LCLE 5B-98G
HFNES 1-3/4MA-01
HFNC 1/2SW45-08
AFA 1-1/4NAA-04B1
HFNE 9DZ-08
BNESB 1SW-04
AAC 1HCW100-01
TRAE 40HAA-10GB1
TRAE 15NW-09
HFNC 1/2RW-08
TER 12HCA-04
For more information,please contact us freely
Emerson Alco Expansion Valve 058135
There is no price at present, you can Request a Quote
People who bought this item also viewed
Emerson Alco Expansion Valve TRAE15HCA
Danfoss Expansion Valve 068Z3386
Danfoss Expansion Valve 068Z3393
Hitachi Compressor SHU40MC2-U
SHAKO Solenoid Valve PU225A-03-S
Amgis Transformer L01-6311
Festo Solenoid Coil MSFW-24-50/60-EX
Schneider Contactor LC1D205E5C
Sanyo Denki Fan 109P0412G6D01
LEEMIN Filter SFX-3900-10
Danfoss Sight Glass SGI 19S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Nidec Fan D08A-24PS1
PARKER Filter 922624Q
ABB Fuse OFALC4GG800
Fuji Fuse CR2L-350/UL
PARKER Hydraulic Motor PGM350 05
Contrinex Sensor BD10-I4S1-M18
Recent related posts
-
01/15/2021
Dafoss high-pressure
High pressure Compressor Compressor discharge pipe too hot Probable bellows leak in KVC capacity regulator. Solution Slowly loosen protective cap. If pressure or traces of refrigerant exist under the cap,there is a leak in the bellows.Replace val
-
01/07/2021
Working principle of air conditioner refrigerator
Working principle of air conditioner refrigerator The basic principle of HVAC chiller using refrigeration For example, the kind used in the laboratory or industrial environment, there are many types of chillers on the market, this is an overview of 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ
-
12/19/2022
The Ultimate Guide to Memory Card Selection
To select the proper memory card, storage, transfer speed, speed class, and price are all factors to consider. Here is a complete guide to determine these factors.
-
09/06/2020
Characteristics and Control of Exhaust Noise of Air Distribution Valve in Pneumatic System
In a pneumatic system, the air intake and exhaust of the cylinder are controlled by an air distribution valve, and the noise generated by the air discharged into the atmosphere through the exhaust port of the distribution valve is often greater than the noise generated by any part of the pneumatic system. And cause serious damage and pollution to the operators and the surrounding environment [2].
-
09/05/2020
What is the basis for the rated flow when selecting the filter
When selecting a filter, the rated capacity should not be selected according to the diameter of the pipe, but the nominal flow of the filter (nameplate flow) should be selected according to the volumetric flow of the compressed air passing through the filter.
-
07/16/2020
Three factors determine the quality of cold storage
The size of the cold storage should be designed according to the highest amount of agricultural products to be stored throughout the year. This capacity is calculated based on the volume that the stored products must occupy in the cold storage, plus the aisles between the rows, the space between the stack and the wall and ceiling, and the gap between the packaging.
-
07/12/2020
What semi-hermetic screw compressors are customers willing to pay for?
In the early years, many people felt that semi-hermetic screw compressors are expensive and have high technical threshold. Without semi-hermetic piston compressors, they are cheap and easy to use and maintain, so they are a bit daunted.
-
08/17/2020
Causes and solutions for high-pressure alarms of refrigerators
Generally, the refrigerator is equipped with a full set of protection devices. When the refrigerator has a high-pressure alarm, it will automatically start the protection device, and the corresponding fault indicator will light up
-
07/14/2020
What's wrong with the freezer not cooling
1. Test the power cord with an electric pen. The broken power cord of the freezer is also a cause of non-refrigeration. For this situation, we need to check whether it is a power problem. The general approach is to open the door and observe whether the lighting lamp in the box Light up. Look for signs of damage to the wires, such as being bitten by a mouse.
-
02/16/2024
Why is My Electric Furnace Blowing Cold Air? 11 Reasons&Ways to Fix
An electric furnace is a reliable and efficient way to keep your home warm during the colder months. However, encountering the issue of your electric furnace blowing cold air can be both frustrating and uncomfortable.